ISO/IEC 14763-4:2021 (E) specifies the measurement of two- and four-pair balanced cabling of
a) end-to-end (E2E) link Class D, E and EA;
b) modular plug terminated links (MPTLs) of Class D, E, EA, F, FA and of Class I and II;
c) direct attach cabling of Class D, E, EA, F, FA and of Class I and II.
The free connectors which terminate two and four pairs in field and laboratory conditions are included. This second edition cancels and replaces the first edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- measurement of the transmission performance of modular plug terminated link (MPTL) and direct attach cabling were added.
- Additional requirements of test head designs of E2E link were introduced.
The contents of the corrigendum 1 (2022-09) have been included in this copy.

  • Standard
    18 pages
    English language
    sale 15% off

ISO/IEC 11801-9903:2021 establishes a matrix-model for formulating limits for mixed mode parameters within and between two pairs of balanced cabling. This is for the purpose of supporting new, improved balanced cabling channel and link specifications.

  • Technical specification
    48 pages
    English language
    sale 15% off

ISO/IEC TR 11801-9906:2020(E) covers channel specifications, for channels constructed from balanced 1 pair cabling components, primarily intended for use in industrial automation and process control applications.
The channel specifications are consistent with corresponding IEEE 802.3 single-pair Ethernet (SPE) applications and are referenced from link segment specifications in the following IEEE SPE physical layer specifications:
• ISO/IEC/IEEE 8802-3:2017/AMD4, 1 000 Mb/s: 1000BASE T1 Type A, ≤ 15 m, 1000BASE T1 Type B, ≤ 40 m;
• ISO/IEC/IEEE 8802-3:2017/AMD1, 100 Mb/s: 100BASE T1, ≤ 15 m;
• IEEE 802.3cg, 10 Mb/s: 10BASE T1S, ≤ 15 m; 10BASE T1L, ≤ 1 000 m.
The channel component specifications are referenced according to corresponding IEC balanced 1 pair cable and connector specifications.
Channel specifications include IL, RL, TCL, coupling attenuation, and alien crosstalk parameters specifications.
Channel EMC related specifications include electromagnetic isolation levels E1, E2 and E3, which are defined according to the MICE standard environmental characterization system specified in ISO/IEC 11801-1

  • Technical report
    38 pages
    English language
    sale 15% off

ISO/IEC 14763-2:2019 specifies requirements for the planning, installation and operation of telecommunications cabling and cabling infrastructures including cabling, pathways, spaces and telecommunications bonds (other than that specified in ISO/IEC 30129) in support of generic cabling standards and associated documents. The following aspects are addressed:
a) specification of the installation;
b) quality assurance;
c) installation planning;
d) installation practice;
e) documentation;
f) administration;
g) testing;
h) inspection;
i) operation;
j) maintenance;
k) repair.
The requirements and recommendations of Clauses 5 to 14 are premises-independent. Annexes C through G contain premises-specific amendments of and additions to these requirements and recommendations.
In addition, this document describes the methodology for the assessment of spaces, pathways, pathway systems and cabling (either installed or planned) in support of remote powering objectives.
This document excludes specific requirements applicable to other cabling systems (e.g. power supply cabling); however, it takes account of the effects other cabling systems may have on the installation of telecommunications cabling (and vice versa) and gives general advice.
This document excludes those aspects of installation associated with the transmission of signals in free space between transmitters, receivers or their associated antenna systems (e.g. wireless, radio, microwave or satellite).
This document is applicable to certain hazardous environments but does not exclude additional requirements which are applicable in particular circumstances (e.g. electricity supply and electrified railways).
Safety and electromagnetic compatibility (EMC) requirements are outside the scope of this document and are covered by other standards and regulations. However, information given in this document can be of assistance in meeting these standards and regulations.
This second edition includes the following significant technical changes with respect to the previous edition: the inclusion of planning and installation practices to support remote powering over the telecommunications cabling infrastructure and the inclusion of planning and installation practices outside buildings.

  • Standard
    175 pages
    English language
    sale 15% off

ISO/IEC 14763-4:2018(E) specifies the measurement at frequencies of end-to-end links of two- and four-pair balanced cabling of 100 MHz of Class D and 250 MHz of Class E including free connectors which terminate two and four pairs in both field and laboratory conditions.

  • Standard
    8 pages
    English language
    sale 15% off

This Technical Report provides guidance to determine whether and which installed channels will support 25GBASE-T. It also provides mitigation procedures to improve the performance of installed channels to the point where the 25GBASE-T application is supported. Additionally, it recommends the use of Class I and Class II channels to support 25GBASE-T in new installations.

  • Technical report
    32 pages
    English language
    sale 15% off

ISO/IEC 11801-6:2017(E) This part of ISO/IEC 11801 specifies generic cabling within premises that comprise single or multiple buildings on a campus. It covers balanced cabling and optical fibre cabling.
The contents of the corrigendum of April 2018 have been included in this copy.

  • Standard
    37 pages
    English language
    sale 15% off

ISO/IEC TS 29125:2017(E) This document specifies the use of generic balanced cabling for customer premises, as specified in the ISO/IEC 11801 series, for remote powering of terminal equipment. It provides guidance on new cabling installations and renovations. The customer premises may encompass one of more buildings or may be within a building that contains more than one organization. The cabling may be installed prior to the seelction of remote powering equipment or powered terminal equipment.

  • Technical specification
    84 pages
    English language
    sale 15% off
  • Technical specification
    26 pages
    English language
    sale 15% off

ISO/IEC TR 11801-9903:2015(E) establishes a matrix-model for formulating limits for differential mode parameters for return loss, insertion loss, and near and far end crosstalk, within and between two pairs of balanced cabling. This is for the purpose of supporting new, improved balanced cabling channel and link specifications, which are expected to be included in the next edition of ISO/IEC 11801.

  • Technical report
    21 pages
    English language
    sale 15% off