The test code applies to the determination of the perfomances of heating boilers combi boilers and water heaters fired by liquid fuels. The requirements are laid down in EN 303-1 and EN 303-2.
This code includesthe requirements and recommendations for carrying out and evaluating the procedure for testing boilers and also the details of the technical conditions under which the tests shall be carried out.
- Draft50 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard49 pagesEnglish language
sale 10% off- e-Library read for1 day
This document applies for decorative fireplaces/appliances for domestic use, producing a flame using alcohol, hereafter referred to as fuel, in liquid or gelatinous fuel for decoration.
NOTE The requirements are strictly applied even when used in other areas. Outside the private household and outdoor area can apply more or different rules on the use of the appliances.
This document applies to free-standing, wall-mounted and built-in appliances with a maximum power output of 4.5 kW.
This docum...view more
- Draft29 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard34 pagesEnglish language
sale 10% off- e-Library read for1 day
This report gives background information about LHO market volumes, fuel specifications, regulations, taxes, duties, logistics and distribution systems for LHO in different European countries.
It assesses the necessity, and whether it is appropriate, to recommend the development of a CEN standard for liquid heating fuels.
- Technical report36 pagesEnglish language
sale 10% off- e-Library read for1 day
EN 1/prA1 covers all points to fulfil the requirements of mandate M/129 under the CPD given from the EC to CEN.
- Amendment14 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment29 pagesEnglish language
sale 10% off- e-Library read for1 day
EN 1/prA1 covers all points to fulfil the requirements of mandate M/129 under the CPD given from the EC to CEN.
- Amendment14 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment29 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard applies to type CX3 central heating boilers as specified in 4.1, equipped with atomizing oil burners:
- Type C13, type C33, and type C53 boilers, including their combustion air supply and combustion products evacuation ducts and their terminals;
- type C43 boilers including their connection ducts but without the chimney which is erected as a shared duct system and which is part of the building;
- type C63 boilers, including the connecting piece as specified in 3.7, if n...view more
- Draft36 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard36 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard applies to type CX3 central heating boilers as specified in 4.1, equipped with atomizing oil burners:
type C13, type C33, and type C53 boilers, including their combustion air supply and combustion products evacuation ducts and their terminals;
type C43 boilers including their connection ducts but without the chimney which is erected as a shared duct system and which is part of the building;
type C63 boilers, including the connecting piece as specified in 3.7, if n...view more
- Draft36 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard36 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the requirements and test methods for the safety and efficiency of oil-fired air heaters using only forced draught oil burners, hereafter referred to as "appliances".
This European Standard applies to stationary and portable appliances. It also applies to appliances intended for outdoor installation. Provision of the heated air may be by means of ducting or may be directly into the heated space.
For the purpose of this standard the heat generation is by the com...view more
- Standard40 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the requirements and test methods for the safety and efficiency of oil-fired air heaters using only forced draught oil burners, hereafter referred to as "appliances".
This European Standard applies to stationary and portable appliances. It also applies to appliances intended for outdoor installation. Provision of the heated air may be by means of ducting or may be directly into the heated space.
For the purpose of this standard the heat generation is by the com...view more
- Standard40 pagesEnglish language
sale 10% off- e-Library read for1 day
This standard applies to flued oil stoves with one or more vaporizing burners (hereafter referred to as 'stoves') as used for individual heating in the domestic field and having either a draught regulator or a combustion air limiter as defined in 3.13 and a nominal heating capacity of not more than 15 kW. It is not applicable for built-in equipment.
- Standard31 pagesEnglish language
sale 10% off- e-Library read for1 day
This standard applies to flued oil stoves with one or more vaporizing burners (hereafter referred to as 'stoves') as used for individual heating in the domestic field and having either a draught regulator or a combustion air limiter as defined in 3.13 and a nominal heating capacity of not more than 15 kW. It is not applicable for built-in equipment.
- Standard31 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard applies for decorative fireplaces/appliances for domestic use, producing a flame using alcohol, hereafter referred to as fuel, in liquid or gelatinous fuel for decoration.
NOTE 1 The requirements are strictly applied even when used in other areas. Outside the private household and outdoor area can apply more or different rules on the use of the appliances.
This European Standard applies to free-standing, wall-mounted and built-in appliances with a maximum power output of...view more
- Amendment10 pagesEnglish language
sale 10% off- e-Library read for1 day
This standard applies to flued oil stoves with one or more vaporizing burners (hereafter referred to as "stoves") as used for individual heating in the domestic field and having either a draught regulator or a combustion air limiter as defined in 3.13 and a nominal heating capacity of not more than 15 kW. This standard also applies to appliances with fan assisted vaporizing burners. This standard does not cover - Built-in appliances - appliances equipped with an atomizing burner - appliances inc...view more
- Draft61 pagesEnglish language
sale 10% off- e-Library read for1 day
This standard applies to flued oil stoves with one or more vaporizing burners (hereafter referred to as "stoves") as used for individual heating in the domestic field and having either a draught regulator or a combustion air limiter as defined in 3.13 and a nominal heating capacity of not more than 15 kW. This standard also applies to appliances with fan assisted vaporizing burners. This standard does not cover - Built-in appliances - appliances equipped with an atomizing burner - appliances inc...view more
- Draft61 pagesEnglish language