Leather — Chemical determination of metal content — Part 1: Extractable metals

ISO 17072-1:2011 specifies a method for the determination of extractable metals in leather using extraction with an acid artificial-perspiration solution and subsequent determination with inductively coupled plasma/optical emission spectrometry (ICP-OES), or inductively coupled plasma/atomic emission spectrometry (ICP/AES), or inductively coupled plasma/mass spectrometry (ICP/MS), or atomic absorption spectrometry (AAS) or spectrometry of atomic fluorescence (SFA). This method is especially suitable for determining the extractable chromium in chromium tanned leathers. This method determines extractable metals in leather, it is not compound-specific or specific to the oxidation state of the metals. This method is also applicable for the determination of many extractable metals, including aluminium (Al), antimony (Sb), arsenic (As), barium (Ba), cadmium (Cd), calcium (Ca), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), magnesium (Mg), manganese (Mn), mercury (Hg), molybdenum (Mo), nickel (Ni), potassium (K), selenium (Se), tin (Sn), titanium (Ti), zinc (Zn), and zirconium (Zr). The quantification limit of extractable lead is 3 mg/kg.

Cuir — Détermination chimique de la teneur en métal — Partie 1: Métaux extractibles

L'ISO 17012-1:2011 spécifie une méthode de détermination des métaux extractibles du cuir s'appuyant sur l'extraction à l'aide d'une solution de sueur artificielle acide suivie d'une détermination par spectrométrie d'émission optique avec plasma à couplage inductif (ICP-OES), ou par spectrométrie d'émission atomique avec plasma à couplage inductif (ICP-AES), ou par spectrométrie de masse avec plasma à couplage inductif (ICP-MS), ou par spectrométrie d'absorption atomique (AAS), ou par spectrométrie de fluorescence atomique (SFA). La présente méthode est particulièrement adaptée à la détermination du chrome extractible dans les cuirs tannés au chrome. La présente méthode détermine les métaux extractibles présents dans le cuir; elle n'est pas spécifique à un composé ou à l'état d'oxydation des métaux. La méthode s'applique également à la détermination de nombreux métaux extractibles, dont: aluminium (Al), antimoine (Sb), arsenic (As), baryum (Ba), cadmium (Cd), calcium (Ca), chrome (Cr), cobalt (Co), cuivre (Cu), fer (Fe), plomb (Pb), magnésium (Mg), manganèse (Mn), mercure (Hg), molybdène (Mo), nickel (Ni), potassium (K), sélénium (Se), étain (Sn), titane (Ti), zinc (Zn) et zirconium (Zr). La limite de quantification du plomb extractible est de 3 mg/kg.

General Information

Status
Withdrawn
Publication Date
30-Jan-2011
Withdrawal Date
30-Jan-2011
Current Stage
9599 - Withdrawal of International Standard
Completion Date
28-Feb-2019
Ref Project

Relations

Buy Standard

Standard
ISO 17072-1:2011 - Leather -- Chemical determination of metal content
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 17072-1:2011 - Cuir -- Détermination chimique de la teneur en métal
French language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 17072-1
IULTCS/IUC
27-1
First edition
2011-02-15


Leather — Chemical determination of
metal content —
Part 1:
Extractable metals
Cuir — Détermination chimique de la teneur en métal —
Partie 1: Métaux extractibles




Reference number
ISO 17072-1:2011(E)
IULTCS/IUC 27-1:2011(E)
©
ISO 2011

---------------------- Page: 1 ----------------------
ISO 17072-1:2011(E)
IULTCS/IUC 27-1:2011(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.

COPYRIGHT PROTECTED DOCUMENT


©  ISO 2011
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland

ii © ISO 2011 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 17072-1:2011(E)
IULTCS/IUC 27-1:2011(E)
Contents Page
Foreword .iv
1 Scope.1
2 Normative references.1
3 Principle.2
4 Reagents .2
5 Apparatus and materials .3
6 Sampling and sample preparation.3
7 Procedure.4
7.1 Preparation of acid artificial-perspiration solution in accordance with ISO 105-E04:2008,
Clause 4.4
7.2 Extraction of leather sample .4
7.3 Digestion of the extracted solution .4
7.4 Analysis by ICP, AAS and SFA .4
7.4.1 ICP.4
7.4.2 AAS .5
7.4.3 Analysis by SFA technique .5
8 Calculation and expression of results .5
9 Test report.6
Annex A (informative) Interlaboratory test results .7
Bibliography.8
© ISO 2011 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 17072-1:2011(E)
IULTCS/IUC 27-1:2011(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 17072-1 was prepared by the European Committee for Standardization (CEN) Technical Committee
CEN/TC 289, Leather, in collaboration with the Chemical Test Commission of the International Union of
Leather Technologists and Chemists Societies (IUC Commission, IULTCS), in accordance with the
Agreement on technical cooperation between ISO and CEN (Vienna Agreement). This method is technically
similar to the method in IUC 27-1.
IULTCS, originally formed in 1897, is a world-wide organization of professional leather societies to further the
advancement of leather science and technology. IULTCS has three Commissions, which are responsible for
establishing international methods for the sampling and testing of leather. ISO recognizes IULTCS as an
international standardizing body for the preparation of test methods for leather.
ISO 17072 consists of the following parts, under the general title Leather — Chemical determination of metal
content:
⎯ Part 1: Extractable metals
⎯ Part 2: Total metal content
iv © ISO 2011 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 17072-1:2011(E)
INTERNATIONAL STANDARD
IULTCS/IUC 27-1:2011(E)

Leather — Chemical determination of metal content —
Part 1:
Extractable metals
1 Scope
This part of ISO 17072 specifies a method for the determination of extractable metals in leather using
extraction with an acid artificial-perspiration solution and subsequent determination with inductively coupled
plasma/optical emission spectrometry (ICP-OES), or inductively coupled plasma/atomic emission
spectrometry (ICP/AES), or inductively coupled plasma/mass spectrometry (ICP/MS), or atomic absorption
spectrometry (AAS) or spectrometry of atomic fluorescence (SFA).
This method is especially suitable for determining the extractable chromium in chromium-tanned leathers.
This method determines extractable metals in leather; it is not compound-specific or specific to the oxidation
state of the metals.
The method is also applicable for the determination of many extractable metals, including:
Aluminium (Al) Copper (Cu) Nickel (Ni)
Antimony (Sb) Iron (Fe) Potassium (K)
Arsenic (As) Lead (Pb) Selenium (Se)
Tin (Sn)
Barium (Ba) Magnesium (Mg)
Cadmium (Cd) Manganese (Mn) Titanium (Ti)
Calcium (Ca) Mercury (Hg) Zinc (Zn)
Chromium (Cr) Molybdenum (Mo) Zirconium (Zr)
Cobalt (Co)

The quantification limit of extractable lead is 3 mg/kg (see Annex A).
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 105-E04:2008, Textiles — Tests for colour fastness — Part E04: Colour fastness to perspiration
ISO 2418, Leather — Chemical, physical and mechanical and fastness tests — Sampling location
ISO 3696:1987, Water for analytical laboratory use — Specification and test methods
© ISO 2011 – All rights reserved 1

---------------------- Page: 5 ----------------------
ISO 17072-1:2011(E)
IULTCS/IUC 27-1:2011(E)
ISO 4044, Leather — Chemical tests — Preparation of chemical test samples
ISO 4684, Leather — Chemical tests — Determination of volatile matter
ISO 11885, Water quality — Determination of selected elements by inductively coupled plasma optical
emission spectrometry (ICP-OES)
ISO 15586, Water quality — Determination of trace metals using atomic absorption spectrometry with graphite
furnace
ISO 17072-2:2011, Leather — Chemical determination of metal content — Part 2: Total metal content
ISO 17294-2, Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) —
Part 2: Determination of 62 elements
ISO 17852, Water quality — Determination of mercury — Method using atomic fluorescence spectrometry
3 Principle
A sample of leather is ground and extracted at 37 °C ± 2 °C for 4 h ± 5 min in an acid artificial-perspiration
solution. The extract solution is filtered, acidified and analysed by ICP, or SFA or AAS. If necessary, digest a
portion of filtrate solution in accordance with ISO 17072-2.
The results are reported on the dry matter of the leather.
If sampling in accordance with ISO 2418 is not possible (e.g. leathers are from finished products like shoes or
...

NORME ISO
INTERNATIONALE 17072-1
IULTCS/IUC
27-1
Première édition
2011-02-15



Cuir — Détermination chimique de la
teneur en métal —
Partie 1:
Métaux extractibles
Leather — Chemical determination of metal content —
Part 1: Extractable metals




Numéro de référence
ISO 17072-1:2011(F)
IULTCS/IUC 27-1:2011(F)
©
ISO 2011

---------------------- Page: 1 ----------------------
ISO 17072-1:2011(F)
IULTCS/IUC 27-1:2011(F)
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.


DOCUMENT PROTÉGÉ PAR COPYRIGHT


©  ISO 2011
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse

ii © ISO 2011 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 17072-1:2011(F)
IULTCS/IUC 27-1:2011(F)
Sommaire Page
Avant-propos .iv
1 Domaine d'application .1
2 Références normatives.1
3 Principe .2
4 Réactifs.2
5 Appareillage et matériel.3
6 Échantillonnage et préparation des échantillons .3
7 Mode opératoire.4
7.1 Préparation d'une solution de sueur artificielle acide conformément à l'ISO 105-E04:2008,
Article 4 .4
7.2 Extraction d'un échantillon de cuir.4
7.3 Digestion de la solution extraite .4
7.4 Analyse par ICP, AAS et SFA .4
7.4.1 ICP.4
7.4.2 AAS .5
7.4.3 Analyse selon la technique SFA .5
8 Calcul et expression des résultats .5
9 Rapport d'essai.6
Annexe A (informative) Résultats de l'essai interlaboratoires.7
Bibliographie.8

© ISO 2011 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 17072-1:2011(F)
IULTCS/IUC 27-1:2011(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 17072-1 a été élaborée par le comité technique CEN/TC 289, Cuir, du Comité européen de
normalisation (CEN), en collaboration avec la Commission des essais chimiques de l'Union internationale des
sociétés de techniciens et chimistes du cuir (commission IUC, IULTCS), conformément à l'Accord de
coopération technique entre l'ISO et le CEN (Accord de Vienne). Cette méthode est techniquement identique
à la méthode IUC 27-1.
L'IULTCS est une organisation mondiale de sociétés professionnelles des industries du cuir fondée en 1897
ayant pour mission de favoriser l'avancement des sciences et technologies du cuir. L'IULTCS a trois
commissions, qui sont responsables de l'établissement des méthodes internationales d'échantillonnage et
d'essai des cuirs. L'ISO reconnaît l'IULTCS en tant qu'organisme international à activités normatives pour
l'élaboration de méthodes d'essai relatives au cuir.
L'ISO 17072 comprend les parties suivantes, présentées sous le titre général Cuir — Détermination chimique
de la teneur en métal:
⎯ Partie 1: Métaux extractibles
⎯ Partie 2: Teneur totale en métaux

iv © ISO 2011 – Tous droits réservés

---------------------- Page: 4 ----------------------
ISO 17072-1:2011(F)
NORME INTERNATIONALE
IULTCS/IUC 27-1:2011(F)

Cuir — Détermination chimique de la teneur en métal —
Partie 1:
Métaux extractibles
1 Domaine d'application
La présente partie de l'ISO 17012 spécifie une méthode de détermination des métaux extractibles du cuir
s'appuyant sur l'extraction à l'aide d'une solution de sueur artificielle acide suivie d'une détermination par
spectrométrie d'émission optique avec plasma à couplage inductif (ICP-OES), ou par spectrométrie
d'émission atomique avec plasma à couplage inductif (ICP-AES), ou par spectrométrie de masse avec
plasma à couplage inductif (ICP-MS), ou par spectrométrie d'absorption atomique (AAS), ou par
spectrométrie de fluorescence atomique (SFA).
La présente méthode est particulièrement adaptée à la détermination du chrome extractible dans les cuirs
tannés au chrome.
La présente méthode détermine les métaux extractibles présents dans le cuir; elle n'est pas spécifique à un
composé ou à l'état d'oxydation des métaux.
La méthode s'applique également à la détermination de nombreux métaux extractibles, dont:
Aluminium (Al) Cuivre (Cu) Nickel (Ni)
Antimoine (Sb) Fer (Fe) Potassium (K)
Arsenic (As) Plomb (Pb) Sélénium (Se)
Baryum (Ba) Magnésium (Mg) Étain (Sn)
Cadmium (Cd) Manganèse (Mn) Titane (Ti)
Calcium (Ca) Mercure (Hg) Zinc (Zn)
Chrome (Cr) Molybdène (Mo) Zirconium (Zr)
Cobalt (Co)
La limite de quantification du plomb extractible est de 3 mg/kg (voir l'Annexe A).
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du
document de référence s'applique (y compris les éventuels amendements).
ISO 105-E04:2008, Textiles — Essais de solidité des teintures — Partie E04: Solidité des teintures à la sueur
ISO 2418, Cuir — Essais chimiques, physiques, mécaniques et de solidité — Emplacement de
l'échantillonnage
ISO 3696:1987, Eau pour laboratoire à usage analytique — Spécification et méthodes d'essai
© ISO 2011 – Tous droits réservés 1

---------------------- Page: 5 ----------------------
ISO 17072-1:2011(F)
IULTCS/IUC 27-1:2011(F)
ISO 4044, Cuir — Essais chimiques — Préparation des échantillons pour essais chimiques
ISO 4684, Cuir — Essais chimiques — Détermination des matières volatiles
ISO 11885, Qualité de l'eau — Dosage d'éléments choisis par spectroscopie d'émission optique avec plasma
induit par haute fréquence (ICP-OES)
ISO 15586, Qualité de l'eau — Dosage des éléments traces par spectrométrie d'absorption atomique en four
graphite
ISO 17072-2:2011, Cuir — Détermination chimique de la teneur en métal — Partie 2: Teneur totale en métaux
ISO 17294-2, Qualité de l'eau — Application de la spectrométrie de masse avec plasma à couplage inductif
(ICP-MS) — Partie 2: Dosage de 62 éléments
ISO 17852, Qualité de l'eau — Dosage du mercure — Méthode par spectrométrie de fluorescence atomique
3 Principe
Un échantillon de cuir est broyé et extrait à 37 °C ± 2 °C pendant 4 h ± 5 min dans une solution de sueur
artificielle acide. La solution extraite est filtrée, acidifiée et analysée, par ICP ou SFA ou AAS. Si nécessaire,
une digestion d'une prise d'essai de la solution filtrée est effectuée conformément à l'ISO 17072-2.
Les résultats sont donnés par rapport à la matière sèche du cuir.
S'il est impossible d'effectuer l'échantillonnage conformément à l'ISO 2418 (par exemple avec des cuirs
prélevés sur des produits finis comme les chaussures, les vêtements), des détails relatifs à l'échantillonnage
doivent être fournis avec le rapport d'essai.
4 Réactifs
AVERTISSEMENT — Des acide
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.