EN 61157:2007
(Main)Standard means for the reporting of the acoustic output of medical diagnostic ultrasonic equipment
Standard means for the reporting of the acoustic output of medical diagnostic ultrasonic equipment
Establishes requirements for the declaration of the acoustic output information: 1.to be presented in technical data sheets supplied to prospective purchasers of equipment by manufacturers; 2.to be declared in the accompanying literature/ manual supplied by manufacturers; 3.as background information to be made available on request to interested parties by manufacturers.
Normverfahren für die Angabe der akustischen Ausgangsgrößen von medizinischen Ultraschalldiagnostikgeräten
Critères normalisés de déclaration des émissions acoustiques des appareils de diagnostic médical à ultrasons
Définit les critères pour la déclaration des informations intéressant les émissions acoustiques: 1. à présenter dans des bordereaux de données techniques fournis par les fabricants aux acheteurs éventuels des appareils; 2. à déclarer dans la documentation/le manuel d'accompagnement fournis par les fabricants; 3. sous la forme d'informations de fond devant être présentées, sur demande, aux parties intéressées par les fabricants.
Standardni načini poročanja o akustičnem izhodu medicinske ultrazvočne diagnostične opreme (IEC 61157:2007)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61157:2008
01-februar-2008
1DGRPHãþD
SIST EN 61157:2002
6WDQGDUGQLQDþLQLSRURþDQMDRDNXVWLþQHPL]KRGXPHGLFLQVNHXOWUD]YRþQH
GLDJQRVWLþQHRSUHPH,(&
Standard means for the reporting of the acoustic output of medical diagnostic ultrasonic
equipment
Normverfahren für die Angabe der akustischen Ausgangsgrößen von medizinischen
Ultraschalldiagnostikgeräten
Moyens normalisés pour la déclaration des émissions acoustiques des appareils de
diagnostic médical à ultrasons
Ta slovenski standard je istoveten z: EN 61157:2007
ICS:
11.040.50 Radiografska oprema Radiographic equipment
11.040.55 'LDJQRVWLþQDRSUHPD Diagnostic equipment
17.140.50 Elektroakustika Electroacoustics
SIST EN 61157:2008 en,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 61157:2008
---------------------- Page: 2 ----------------------
SIST EN 61157:2008
EUROPEAN STANDARD
EN 61157
NORME EUROPÉENNE
November 2007
EUROPÄISCHE NORM
ICS 11.040.50; 11.140.50 Supersedes EN 61157:1994
English version
Standard means for the reporting of the acoustic output
of medical diagnostic ultrasonic equipment
(IEC 61157:2007)
Moyens normalisés pour la déclaration Normverfahren für die Angabe
des émissions acoustiques des appareils der akustischen Ausgangsgrößen
de diagnostic médical à ultrasons von medizinischen
(CEI 61157:2007) Ultraschalldiagnostikgeräten
(IEC 61157:2007)
This European Standard was approved by CENELEC on 2007-10-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61157:2007 E
---------------------- Page: 3 ----------------------
SIST EN 61157:2008
EN 61157:2007 – 2 –
Foreword
The text of document 87/356/CDV, future edition 2 of IEC 61157, prepared by IEC TC 87, Ultrasonics,
was submitted to the IEC-CENELEC parallel Unique Acceptance Procedure and was approved by
CENELEC as EN 61157 on 2007-10-01.
This European Standard supersedes EN 61157:1994.
The changes with respect to EN 61157:1994 are listed below:
– maintenance on this standard and the referenced standards EN 61161 and EN 62127-1;
– a clause on compliance has been added.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2008-07-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2010-10-01
NOTE The following print types are used:
– Requirements: in roman type
– Test specifications: in italic type
– Notes: in small roman type
– Words in bold in the text are defined in Clause 3.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61157:2007 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 61689 NOTE Harmonized as EN 61689:2007 (not modified).
IEC 61828 NOTE Harmonized as EN 61828:2001 (not modified).
__________
---------------------- Page: 4 ----------------------
SIST EN 61157:2008
– 3 – EN 61157:2007
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.