Railway applications - Current collection systems - Requirements for and validation of measurements of the dynamic interaction between pantograph and overhead contact line

This European Standard specifies the functional requirements for output and accuracy of measurements of the dynamic interaction between pantograph and overhead contact line.

Bahnanwendungen - Stromabnahmesysteme - Anforderungen und Validierung von Messungen des dynamischen Zusammenwirkens zwischen Stromabnehmer und Oberleitung

Applications ferroviaires - Systèmes de captage de courant - Prescriptions et validation des mesures de l'interaction dynamique entre le pantographe et la caténaire

Železniške naprave - Sistemi za odjem toka - Zahteve in veljavnost meritev medsebojnih dinamičnih vplivov med odjemnikom toka in kontaktnim vodnikom

Ta evropski standard določa funkcionalne zahteve za rezultate in natančnost meritev medsebojnih dinamičnih vplivov med odjemnikom toka in kontaktnim vodnikom.

General Information

Status
Published
Publication Date
19-Jan-2012
Withdrawal Date
25-Dec-2014
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
14-Sep-2022

Relations

Buy Standard

Standard
EN 50317:2012
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN 50317:2010
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50317:2012
01-marec-2012
1DGRPHãþD
SIST EN 50317:2003
SIST EN 50317:2003/A1:2005
SIST EN 50317:2003/A2:2007
äHOH]QLãNHQDSUDYH6LVWHPL]DRGMHPWRND=DKWHYHLQYHOMDYQRVWPHULWHY
PHGVHERMQLKGLQDPLþQLKYSOLYRYPHGRGMHPQLNRPWRNDLQNRQWDNWQLPYRGQLNRP
Railway applications - Current collection systems - Requirements for and validation of
measurements of the dynamic interaction between pantograph and overhead contact line
Bahnanwendungen - Stromabnahmesysteme - Anforderungen und Validierung von
Messungen des dynamischen Zusammenwirkens zwischen Stromabnehmer und
Oberleitung
Applications ferroviaires - Systèmes de captage de courant - Prescriptions et validation
des mesures de l'interaction dynamique entre le pantographe et la caténaire
Ta slovenski standard je istoveten z: EN 50317:2012
ICS:
29.280 (OHNWULþQDYOHþQDRSUHPD Electric traction equipment
SIST EN 50317:2012 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 50317:2012

---------------------- Page: 2 ----------------------

SIST EN 50317:2012

EUROPEAN STANDARD
EN 50317
NORME EUROPÉENNE
January 2012
EUROPÄISCHE NORM

ICS 29.280; 45.060.10 Supersedes EN 50317:2002 + A1:2004 + A2:2007


English version


Railway applications -
Current collection systems -
Requirements for and validation of measurements of the dynamic
interaction between pantograph and overhead contact line



Applications ferroviaires -  Bahnanwendungen -
Systèmes de captage de courant - Stromabnahmesysteme -
Prescriptions et validation des mesures de Anforderungen und Validierung von
l'interaction dynamique entre le Messungen des dynamischen
pantographe et la caténaire Zusammenwirkens zwischen
Stromabnehmer und Oberleitung






This European Standard was approved by CENELEC on 2011-12-26. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50317:2012 E

---------------------- Page: 3 ----------------------

SIST EN 50317:2012
EN 50317:2012 – 2 –
Contents
Foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Abbreviations and symbols . 5
5 General . 6
6 Measurement of total mean uplift force . 7
7 Measurement of contact force . 8
7.1 General requirements . 8
7.2 Aerodynamic influence of the measurement system .
...

SLOVENSKI STANDARD
oSIST prEN 50317:2010
01-april-2010
äHOH]QLãNHQDSUDYH6LVWHPL]DRGMHPWRND=DKWHYHLQYHOMDYQRVWPHULWHY
PHGVHERMQLKGLQDPLþQLKYSOLYRYPHGRGMHPQLNRPWRNDLQNRQWDNWQLPYRGQLNRP
Railway applications - Current collection systems - Requirements for and validation of
measurements of the dynamic interaction between pantograph and overhead contact line
Bahnanwendungen - Stromabnahmesysteme - Anforderungen und Validierung von
Messungen des dynamischen Zusammenwirkens zwischen Stromabnehmer und
Oberleitung
Applications ferroviaires - Systèmes de captage de courant - Prescriptions et validation
des mesures de l'interaction dynamique entre le pantographe et la caténaire
Ta slovenski standard je istoveten z: prEN 50317:2010
ICS:
29.280 (OHNWULþQDYOHþQDRSUHPD Electric traction equipment
oSIST prEN 50317:2010 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 50317:2010

---------------------- Page: 2 ----------------------
oSIST prEN 50317:2010
 DRAFT
EUROPEAN STANDARD
prEN 50317

NORME EUROPÉENNE
February 2010
EUROPÄISCHE NORM

ICS Will supersede EN 50317:2002 + A1:2004 + A2:2007


English version


Railway applications -
Current collection systems -
Requirements for and validation of measurements of the dynamic
interaction between pantograph and overhead contact line



Applications ferroviaires - Bahnanwendungen -
Systèmes de captage de courant - Stromabnahmesysteme -
Prescriptions et validation des mesures Anforderungen und Validierung
de l'interaction dynamique entre le von Messungen des dynamischen
pantographe et la caténaire Zusammenwirkens zwischen
Stromabnehmer und Oberleitung


This draft European Standard is submitted to CENELEC members for CENELEC enquiry.
Deadline for CENELEC: 2010-07-23.

It has been drawn up by CLC/SC 9XC.

If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national
standard without any alteration.

This draft European Standard was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own
language and notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to
change without notice and shall not be referred to as a European Standard.


CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: Avenue Marnix 17, B - 1000 Brussels


© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Project: 21986 Ref. No. prEN 50317:2010 E

Draft for Enquiry

---------------------- Page: 3 ----------------------
oSIST prEN 50317:2010
prEN 50317:2010 – 2 –
1 Foreword
2 This draft European Standard was prepared by SC 9XC, Electric supply and earthing systems for public
3 transport equipment and ancillary apparatus (Fixed installations), of Technical Committee CENELEC TC 9X,
4 Electrical and electronic applications for railways. It is submitted to the CENELEC enquiry.
5 This document will supersede EN 50317:2002 + A1:2004 + A2:2007.
6 This draft European Standard has been prepared under a mandate given to CENELEC by the European
7 Commission and the European Free Trade Association and covers essential requirements of EC Directive
8 2008/57/EC. See Annex ZZ.
9 __________

Draft for Enquiry

---------------------- Page: 4 ----------------------
oSIST prEN 50317:2010
– 3 – prEN 50317:2010
10 Contents
11 Page
12 Contents . 3
13 1 Scope . 4
14 2 Normative references .
...

Questions, Comments and Discussion