This document specifies requirements for ten classes, four grades and seven types of wire- or textile-reinforced hydraulic hoses and hose assemblies of nominal sizes ranging from 5 to 102. Each class has a single maximum working pressure for all sizes. They are suitable for use with: — oil-based hydraulic fluids HH, HL, HM, HR and HV as defined in ISO 6743‑4 at temperatures ranging from −40 °C to +100 °C for types AS, AC, BS and BC hoses and from −40 °C to +120 °C for types CS, CC and DC hoses. — water-based fluids HFC, HFAE, HFAS and HFB as defined in ISO 6743‑4 at temperatures ranging from −40 °C to +70 °C. — water at temperatures ranging from 0 °C to +70 °C. This document does not include requirements for the connection ends. It is limited to the performance of hoses and hose assemblies. The hose assembly maximum working pressure is governed by the lowest maximum working pressure of the components. NOTE It is the responsibility of the user, in consultation with the hose manufacturer, to establish the compatibility of the hose with the fluid to be used.

  • Standard
    16 pages
    English language
    sale 15% off
  • Standard
    16 pages
    French language
    sale 15% off
  • Draft
    16 pages
    English language
    sale 15% off

This document defines terms used in the hose industry. Recommended terminology for electrical conductivity and resistance of rubber and plastics hoses and hose assemblies can be found in ISO 8031:2020, Annex A.

  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    27 pages
    French language
    sale 15% off
  • Draft
    29 pages
    English language
    sale 15% off

This document specifies methods of measuring the inside diameter, outside diameter (including diameter over reinforcement of hydraulic hoses), wall thickness, concentricity and lining and cover thickness of hoses, methods of measurement and identification of the lengths of hoses and hose assemblies, and a method of verifying the through-bore of hydraulic hose assemblies.

  • Standard
    11 pages
    English language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off
  • Draft
    11 pages
    English language
    sale 15% off
  • Draft
    12 pages
    French language
    sale 15% off

This document specifies a method for the determination of the volumetric expansion of rubber or plastics hoses under hydrostatic pressure. This document does not specify the dimensions of the test piece and the test pressure(s) as each of which is specified in the appropriate specification.

  • Standard
    4 pages
    English language
    sale 15% off
  • Standard
    4 pages
    French language
    sale 15% off
  • Draft
    4 pages
    English language
    sale 15% off

This document specifies requirements for four types of thermoplastic multi-layer (non-vulcanized) hoses and hose assemblies for carrying hydrocarbons, solvents and chemicals. It specifies bore sizes from 25 mm to 300 mm, working pressures from 0,4 MPa (4 bar) to 1,4 MPa (14 bar) and working temperatures from −30 °C to 150 °C, according to type. Type 1 hoses are suitable for vapour applications. Types 2 to 4 hoses are suitable for liquid applications. NOTE 1 See Annex A concerning the selection of the material for the inner wall of layers and any polymeric coating of the internal wire helix related to the chemical(s) to be conveyed by the hoses and/or hose assemblies. NOTE 2 It is intended that the manufacturer be consulted where a polymeric coated internal wire is being considered for use with low conductivity hydrocarbons or chemicals. This document does not apply to hoses and hose assemblies for: — aircraft refuelling (see ISO 1825); — fuel dispensing (see ISO 5772); — oil burners (see ISO 6806); — liquefied petroleum gas and liquefied natural gas (see ISO 27127); — fire fighting (see ISO 14557); — offshore liquefied natural gas (see EN 1474-2); — refrigeration circuits.

  • Standard
    23 pages
    English language
    sale 15% off
  • Draft
    23 pages
    English language
    sale 15% off

This document specifies requirements for two types of thermoplastic multi-layer (non-vulcanized) transfer hoses and hose assemblies for carrying liquefied petroleum gas and liquefied natural gas. Each type is subdivided into two classes, one for onshore duties, and the other for offshore. — Class A hose is for use onshore. — Class B hose is for use offshore. This document is applicable for hose sizes from 25 mm to 250 mm, working pressures from 10,5 bar to 25 bar and operating temperatures from −196 °C to +45 °C, according to class. NOTE Offshore liquefied natural gas (LNG) hose assemblies are also specified in EN 1474-2. EN 1474-2 does not only specify offshore use, but also ship to shore and other LNG transfer applications.

  • Standard
    20 pages
    English language
    sale 15% off
  • Draft
    20 pages
    English language
    sale 15% off

This document specifies the test requirements and the test methods for extruded thermoplastic tubing and hoses for use in vehicles powered by internal-combustion engines, excluding use in air braking systems (see ISO 7628), fuel lines (see ISO 13775-2), and high-pressure hydraulic systems. This document is intended especially for use by original equipment manufacturers (OEMs).

  • Standard
    13 pages
    English language
    sale 15% off
  • Draft
    13 pages
    English language
    sale 15% off

This document specifies the requirements for two groups of rubber hoses and rubber hose assemblies for loading and discharge of liquid hydrocarbon fuels with a maximum working pressure of 1,0 MPa (10 bar). Both groups of hoses are designed for a) use with hydrocarbon fuels having an aromatic-hydrocarbon content not exceeding 50 % by volume and containing up to 15 % of oxygenated compounds, and b) operation within the temperature range of −30 °C to +70 °C, undamaged by climatic conditions of −50 °C to +70 °C when stored in static conditions. NOTE Hoses for use at temperatures lower than −30 °C can be the subject of discussion between manufacturer and end user. This document is not applicable to hoses and hose assemblies for LPG systems, aviation fuel systems, fuel station systems or marine applications.

  • Standard
    14 pages
    English language
    sale 15% off
  • Draft
    14 pages
    English language
    sale 15% off

This document specifies two methods for measuring the stiffness and one method for the determination of the flexibility of rubber and plastics hoses and tubing when they are bent to a specific radius at sub-ambient temperatures. Method A is suitable for non-collapsible rubber and plastics hoses and tubing with a bore of up to and including 25 mm. This method provides a means of measuring the stiffness of the hose or tubing when the temperature is reduced from a standard laboratory temperature. Method B is suitable for rubber and plastics hoses and tubing with a bore of up to 100 mm and provides a means of assessing the flexibility of the hose or tubing when bent around a mandrel at a specified sub-ambient temperature. It can also be used as a routine quality control test. Method C is suitable for rubber and plastics hoses and tubing with a bore of 100 mm and greater. This method provides a means of measuring the stiffness of the hose and tubing at sub-ambient temperatures. This method is only suitable for hoses and tubing which are non-collapsible.

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    10 pages
    French language
    sale 15% off
  • Draft
    10 pages
    English language
    sale 15% off
  • Draft
    10 pages
    French language
    sale 15% off

This document specifies methods for the hydrostatic testing of rubber and plastics hoses and hose assemblies, including methods for the determination of dimensional stability.

  • Standard
    9 pages
    English language
    sale 15% off
  • Standard
    10 pages
    French language
    sale 15% off
  • Draft
    9 pages
    English language
    sale 15% off
  • Draft
    9 pages
    French language
    sale 15% off

This document specifies requirements for two types of reinforced hoses and hose assemblies of nominal size from 3,2 to 25, dependent on relation of minimum burst pressure to maximum working pressure. Each type is divided into classes dependent on maximum working pressure. They are suitable for use with: — oil-based hydraulic fluids HH, HL, HM, HR and HV as defined in ISO 6743-4 at temperatures ranging from −40 °C to +100 °C; — water-based fluids HFC, HFAE, HFAS and HFB as defined in ISO 6743-4 at temperatures ranging from 0 °C to +70 °C; — water at temperatures ranging from 0 °C to +70 °C. Such hoses and hose assemblies are intended to be used for: — water jetting and water blasting applications; — hydraulic applications. This document does not include requirements for end fittings. It is limited to the performance of hoses and hose assemblies. NOTE 1 It is the responsibility of the user, in consultation with the hose manufacturer, to establish the compatibility of the hose with the fluid to be used. NOTE 2 For hydraulic jacks with manually driven pumps, hoses and hose assemblies per ISO 16301 can be used.

  • Standard
    13 pages
    English language
    sale 15% off
  • Draft
    13 pages
    English language
    sale 15% off

This document specifies three methods for determining the resistance to vacuum of hoses and hose assemblies manufactured from plastic or rubber. Applicable dimensions of hoses for each method are as follows: — method A for hoses of nominal size up to and including 80; — method B for hoses of nominal size greater than 80; — method C for hoses of all dimensions. If not otherwise specified in the product standard, method C can be used as an alternative to methods A and B. Methods A and B can also be used to check the adhesion of the lining to the reinforcement (delamination) in a length of hard-wall hose or hose assembly.

  • Standard
    5 pages
    English language
    sale 15% off
  • Standard
    5 pages
    French language
    sale 15% off
  • Draft
    5 pages
    English language
    sale 15% off
  • Draft
    5 pages
    French language
    sale 15% off

This document establishes the requirements and test methods for rubber and plastics suction hoses for fire-fighting purposes. These hoses can also be used manually to supply unpressurized water to the pump or for water discharge. NOTE All pressures are expressed in megapascals and in bar (1 MPa = 10 bar). Additional requirements are specified for hose assemblies, that is, hoses with couplings already fitted, where this is carried out by the hose manufacturer (see Clause 8). Type A (rubber) hoses are intended for use at a minimum temperature of −20 °C and Type B (thermoplastics) hoses are intended for use at a minimum temperature of −10 °C.

  • Standard
    18 pages
    English language
    sale 15% off
  • Standard
    20 pages
    French language
    sale 15% off
  • Draft
    18 pages
    English language
    sale 15% off
  • Draft
    20 pages
    French language
    sale 15% off

This document specifies requirements for rubber hoses and rubber hose assemblies used for the transfer of liquefied petroleum gas (LPG) in the liquid or gaseous phase and natural gas and designed for use at working pressures ranging from vacuum to a maximum of 2,5 MPa (25 bar) within the temperature range −30 °C to +70 °C or, for low-temperature hoses (designated -LT), within the temperature range −50 °C to +70 °C.

  • Standard
    12 pages
    English language
    sale 15% off
  • Draft
    12 pages
    English language
    sale 15% off

This document specifies the requirements for rubber hoses and hose assemblies for wet and dry sand and grit blasting, suitable for use up to a maximum working pressure of 0,63 MPa (6,3 bar) and over an operating temperature range of −25 °C to +70 °C.

  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off
  • Draft
    7 pages
    English language
    sale 15% off
  • Draft
    8 pages
    French language
    sale 15% off

This document specifies the requirements for rubber or thermoplastic hoses and hose assemblies used for circulating liquid and gaseous R1234yf (tetrafluoropropene) in the air-conditioning systems of automobiles. The hoses and hose assemblies are designed in such a way as to restrict losses of refrigerant and contamination of the system. The operational temperature range is −40 °C to +125 °C. Due to the critical relationship between the hose and coupling for this application, a requirement that the coupling to be used in service be used for testing has been laid down.

  • Standard
    28 pages
    English language
    sale 15% off

This document specifies requirements for three types of textile-reinforced thermoplastics hoses and hose assemblies of nominal size from 3,2 to 25. Each type is divided into two classes dependent on electrical conductivity requirements. They are suitable for use with: — oil-based hydraulic fluids HH, HL, HM, HR and HV as defined in ISO 6743‑4 at temperatures ranging from −40 °C to +93 °C; — water-based fluids HFC, HFAE, HFAS and HFB as defined in ISO 6743‑4 at temperatures ranging from 0 °C to +60 °C — water at temperatures ranging from 0 °C to +60 °C. This document does not include any requirements for end fittings. It is limited to the performance of hoses and hose assemblies. NOTE It is the responsibility of the user, in consultation with the hose manufacturer, to establish the compatibility of the hose with the fluid to be used.

  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off
  • Draft
    13 pages
    English language
    sale 15% off

This document specifies electrical test methods for rubber and plastics hoses, tubing and hose assemblies to determine the resistance of conductive, antistatic and non-conductive hoses and the electrical continuity or discontinuity between metal end fittings. All the test methods described for rubber hoses in this document can also be applied to plastics hoses.

  • Standard
    16 pages
    English language
    sale 15% off
  • Standard
    16 pages
    French language
    sale 15% off
  • Draft
    16 pages
    English language
    sale 15% off

This document specifies requirements for five types of textile-reinforced hydraulic hoses and hose assemblies of nominal size from 5 to 100. They are suitable for use with: — oil-based hydraulic fluids HH, HL, HM, HR and HV as defined in ISO 6743‑4 at temperatures ranging from −40 °C to +100 °C; — water-based fluids HFC, HFAE, HFAS and HFB as defined in ISO 6743‑4 at temperatures ranging from −40 °C to +70 °C; — water at temperatures ranging from 0 °C to +70 °C. This document does not include requirements for end fittings. It is limited to requirements for hoses and hose assemblies. NOTE It is the responsibility of the user, in consultation with the hose manufacturer, to establish the compatibility of the hose with the fluid to be used.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    13 pages
    English language
    sale 15% off

This document specifies requirements for wire-reinforced hoses and hose assemblies for underground coal mining applications of nominal sizes 6,3 to 51 for use with: — oil-based hydraulic fluids HH, HL, HM, HR and HV as defined in ISO 6743-4 at temperatures ranging from −40 °C to +120 °C; — water-based fluids HFC, HFAE, HFAS and HFB as defined in ISO 6743-4 at temperatures ranging from −40 °C to +70 °C; — water at temperatures ranging from 0 °C to +70 °C. There is a possibility that operation at the extremes of or outside these temperature ranges materially reduce the life of the hose. These hoses are not suitable for use with fluids that have a castor oil or ester base.

  • Standard
    4 pages
    English language
    sale 15% off
  • Standard
    4 pages
    English language
    sale 15% off

This document specifies requirements for six types of wire-braid-reinforced hoses and hose assemblies of nominal size from 5 to 51. This document also specifies the hose of nominal size 63 for types 2SN and R2AT, and the hose of nominal size 76 for type 2SN. They are suitable for use with: — oil-based hydraulic fluids HH, HL, HM, HR and HV as defined in ISO 6743‑4 at temperatures ranging from −40 °C to +100 °C; — water-based fluids HFC, HFAE, HFAS and HFB as defined in ISO 6743‑4 at temperatures ranging from −40 °C to +70 °C; — water at temperatures ranging from 0 °C to +70 °C. This document does not include requirements for end fittings. It is limited to requirements for hoses and hose assemblies. NOTE It is the responsibility of the user, in consultation with the hose manufacturer, to establish the compatibility of the hose with the fluid to be used.

  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    13 pages
    English language
    sale 15% off

This document specifies requirements for five types of spiral-wire-reinforced hydraulic hoses and hose assemblies of nominal size from 6,3 to 51. They are suitable for use with: — oil-based hydraulic fluids HH, HL, HM, HR and HV as defined in ISO 6743-4 at temperatures ranging from −40 °C to +100 °C for types 4SP and 4SH hoses and from −40 °C to +120 °C for types R12, R13 and R15 hoses; — water-based fluids HFC, HFAE, HFAS and HFB as defined in ISO 6743-4 at temperatures ranging from −40 °C to +70 °C; — water at temperatures ranging from 0 °C to +70 °C. This document does not include requirements for end fittings. It is limited to requirements for hoses and hose assemblies. NOTE It is the responsibility of the user, in consultation with the hose manufacturer, to establish the compatibility of the hose with the fluid to be used.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    13 pages
    English language
    sale 15% off

This document specifies the requirements for rubber hoses and hose assemblies, up to a maximum hose size of 19, for use in motor vehicles with liquefied petroleum gas (LPG) installations. The hoses are designed for use up to a maximum working pressure of 3,0 MPa (30 bar) and at working temperatures from −40 °C up to and including +80 °C.

  • Standard
    9 pages
    English language
    sale 15% off

This document specifies the requirements for three types of general-purpose textile-reinforced rubber water hose with an operating temperature range of −25 °C to +70 °C and a maximum working pressure of up to 2,5 MPa (25 bar). These hoses are not intended to be used for conveyance of potable (drinking) water, for washing-machine inlets, as firefighting hoses, for special agricultural machines or as collapsible water hoses. These hoses can be used with additives which lower the freezing point of water.

  • Standard
    4 pages
    English language
    sale 15% off
  • Standard
    4 pages
    French language
    sale 15% off

This document specifies the requirements for rubber tubing and hoses used in diesel fuel circuits for internal combustion engines. The diesel fuels covered include "bio-diesels" which consist of the methyl ester of rape seed oil at levels up to 20 % by volume in conventional diesel fuels. This document can also be applied as a classification system to enable original equipment manufacturers (OEMs) to detail a "line call-out" of tests for specific applications where these are not covered by the main types specified (see example in Annex E). In this case, the hose or tubing would not carry any marking showing the number of this document but can detail the OEM's own identification markings as shown on their part drawings.

  • Standard
    17 pages
    English language
    sale 15% off

This document specifies requirements for five types of hose and hose assembly used in automobile power-steering systems, the five types differing in their pressure ratings and volumetric expansion. They are for use with fluids in the temperature range −40 °C to +135 °C. This document is based on performance tests. In order to take account of technological developments, no requirements are included for specific materials, detailed construction or manufacturing methods.

  • Standard
    10 pages
    English language
    sale 15% off

This document describes hose impulse testing, with flexing, of rubber or plastics hydraulic hose assemblies at both high and low impulse pressures. The high-pressure testing is carried out at pressures greater than 3 MPa and the low-pressure testing at pressures from 1,5 MPa to 3 MPa. The test procedure is applicable to hydraulic hose assemblies that are subject to pulsating pressures in service which are included in the product requirements. NOTE Impulse test procedures without flexing can be found in ISO 6803.

  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    7 pages
    French language
    sale 15% off
  • Standard
    7 pages
    French language
    sale 15% off

ISO 28017:2018 specifies requirements for two types, seven classes and three grades of wire- or textile-reinforced dredging hoses with nominal sizes ranging from 100 to 1 200. Within each class, all grades and sizes have the same maximum working pressure. Such hoses are suitable for the delivery or suction of seawater or freshwater mixed with silt, sand, coral and small stones with a specific gravity in the range from 1,0 to 2,3 at ambient temperatures ranging from −10 °C to +40 °C. ISO 28017:2018 covers two types of hose, as follows: - type 1: floating type, for delivery only, which includes flotation material to give the hose buoyancy; - type 2: submarine type for delivery and suction. ISO 28017:2018 does not specify requirements concerning the service life of hoses or hose assemblies. Specifying such requirements is the responsibility of the customer, in consultation with the hose manufacturer.

  • Standard
    18 pages
    English language
    sale 15% off
  • Standard
    20 pages
    French language
    sale 15% off

ISO 10619-1:2017 specifies three methods for measuring the flexibility of rubber and plastics hoses and tubing (methods A1, B and C1), where the deformation of the hose or tubing is measured, and two methods for measuring the stiffness (methods A2 and C2) by measuring the force required to bend rubber or plastics hoses or tubing to a specific radius at ambient temperature. Methods A1 and A2 are suitable for rubber and plastics hoses and tubing with inside diameter of up to and including 80 mm. Method A1 allows the measurement of the flexibility of the hose or tubing by measuring the reduction in outside diameter when the hose is compressed between two plates. Method A2 provides a means of measuring the force required to reach a specific bend radius when the hose or tubing is compressed, as between two plates. The test can be carried out at a specified internal pressure. Method B is suitable for rubber and plastics hoses and tubing with inside diameter of up to and including 100 mm, and provides a means of assessing the behaviour of the hose and tubing when bent around a mandrel. The final mandrel diameter used can be taken as the minimum bend radius of the hose or tubing. As this value is determined by the reduction of the outside diameter, it can be used as a measure of the flexibility of the hose or tubing. The hose or tubing being tested can be unpressurized, pressurized or under vacuum and, if required, with the curvature or against the curvature of the hose or tubing, if such curvature is present. Methods C1 and C2 are suitable for rubber and plastics hoses and tubing with inside diameter of 100 mm and greater. Method C1 provides a means of determining the flexibility of the hose and tubing at the minimum bend radius. Method C2 provides a method of measuring the stiffness of the hose and tubing at the minimum bend radius.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off

ISO 23297:2017 specifies requirements for eight classes and two types (construction with adhesive bond between layers and construction without adhesive bond between layers) of wire or synthetic yarn reinforced hydraulic hoses and hose assemblies of nominal size from 3,2 to 31,5. Each class has a single maximum working pressure for all sizes. Such hoses are suitable for use with hydraulic fluids HH, HL, HM, HR, and HV as defined in ISO 6743‑4 at temperatures ranging from −40 °C to +100 °C for grades A and B and −40 °C to +120 °C for grades C and D. ISO 23297:2017 does not include requirements for end fittings. It is limited to the performance of hoses and hose assemblies. The hose assembly maximum working pressure is governed by the lowest maximum working pressure of the components. NOTE It is the responsibility of the user, in consultation with the hose manufacturer, to establish compatibility of the hose with the fluid to be used.

  • Standard
    13 pages
    English language
    sale 15% off

ISO 8028:2017 specifies the requirements for four types of hose and hose assemblies for use in airless paint spraying. The four types are differentiated by burst pressure and operating temperature, and can be constructed from rubber or plastic materials, or a combination of rubber and plastic material.

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off

ISO 10960:2017 specifies a method of assessing the resistance of hoses to the deleterious effects of atmospheric ozone under dynamic conditions. It is applicable to hoses with bore diameters up to and including 25 mm.

  • Standard
    3 pages
    English language
    sale 15% off
  • Standard
    3 pages
    French language
    sale 15% off

ISO 1825:2017 specifies the dimensions and construction of, and requirements for, four types of hose and hose assembly for use in all operations associated with the ground fuelling and defuelling of aircraft. All four types are designed for: a) use with petroleum fuels having an aromatic-hydrocarbon content not exceeding 30 % by volume; b) operation within the temperature range of −30 °C to +65 °C and such that they will be undamaged by climatic conditions of −40 °C to +70 °C when stored in static conditions; c) operation at up to 2,0 MPa (20 bar) maximum working pressure, including surges of pressure which the hose can be subjected to in service. NOTE 1 Type C hoses are intended for general pressure applications on all vehicles used for plane fuelling. They can also be used for vehicle/rail car loading and discharge where excessive vacuum does not occur. NOTE 2 Type F hoses can be used for plane delivery applications on vehicles that are also used for defuelling at high flow rates where type C hoses are not suitable. NOTE 3 Type E and F hoses can also be used for vehicle/rail car loading and discharge, for trailer to fueller transfer and for elevation platform supply (riser) to provide greater kink resistance.

  • Standard
    27 pages
    English language
    sale 15% off
  • Standard
    29 pages
    French language
    sale 15% off

ISO 16301 specifies the requirements for three classes of wire- or textile-reinforced hydraulic hoses and hose assemblies of nominal sizes ranging from 5 to 25. The hoses and hose assemblies are used in hydraulic jack applications with manually operated hand pumps. They are suitable for use with hydraulic fluids HH, HL, HM, HR and HV at temperature ranging from −40 °C to +55 °C. For tools that require heavy duty services such as a rescue tool, ISO 19718[3] applies. ISO 16301 does not include requirements for the connection ends. It is limited to the performance of hoses and hose assemblies. The maximum working pressure of hose assemblies is regulated by the lowest maximum working pressure of the components. NOTE 1 It is the responsibility of the user, in consultation with the hose manufacturer, to establish the compatibility of the hose with the fluid to be used. NOTE 2 There are two International Standards for hoses for hydraulic jacks and tool applications, i.e. ISO 16301 and ISO 19718. The comparison table is given in Annex A. NOTE 3 The classification of HH, HL, HM, HR and HV is found in ISO 6743-4[2].

  • Standard
    17 pages
    English language
    sale 15% off

ISO 11237 specifies requirements for five types of compact, wire-braid-reinforced hose and hose assembly of nominal size from 5 to 31,5. They are suitable for use with - oil-based hydraulic fluids HH, HL, HM, HR and HV as defined in ISO 6743-4 at temperatures ranging from −40 °C to +100 °C; - water-based fluids HFC, HFAE, HFAS and HFB as defined in ISO 6743-4 at temperatures ranging from 0 °C to +60 °C; - water at temperatures ranging from 0 °C to +60 °C. ISO 11237 does not include requirements for end fittings. It is limited to requirements for hoses and hose assemblies. NOTE It is the responsibility of the user, in consultation with the hose manufacturer, to establish the compatibility of the hose with the fluid to be used.

  • Standard
    11 pages
    English language
    sale 15% off

ISO 6806:2017 specifies the minimum requirements for rubber hoses and hose assemblies for use in oil burners. The following two types of hose assembly are specified. - Type 1: Hose assemblies for flux and reflux, but not for insertion between the oil burner pump and the atomizing connection; maximum working pressure 1,0 MPa (10 bar); maximum oil temperature 100 °C. - Type 2: Hose assemblies for insertion between the oil burner pump and the atomizing connection; maximum working pressure 4,0 MPa (40 bar); maximum oil temperature 100 °C. The hose assemblies specified in this document are not intended to be used, without special assessment, for purposes other than oil burner installations.

  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off

ISO 6803:2017 describes hose impulse testing, without flexing, of rubber or plastics hydraulic hose assemblies at both high and low impulse pressures. The high-pressure testing is carried out at pressures greater than 3 MPa and the low-pressure testing at pressures from 1,5 MPa to 3 MPa. The test procedure is applicable to hydraulic hose assemblies that are subject to pulsating pressures in service which are included in the product requirements. NOTE Impulse test procedures with flexing can be found in ISO 6802.

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off

ISO 11424:2017 specifies requirements for rubber hoses and tubing for use in the various air and vacuum systems found on internal combustion engines. This document does not cover hoses used for direct power-brake actuation in trucks and trailers, nor for air intakes and ducting within the passenger compartment. The highest-temperature hoses are generally used for turbocharger applications. All hoses and tubing remain serviceable down to −40°C. NOTE Although the term vacuum is generally used, in reality the application is one of reduced air pressure used for the purposes of actuation or monitoring of the various engine-system components. The air carried by the tubing or hoses may be clean and free of contaminants but may also contain oil, fuel and their vapours as contamination, due to the particular installation and application.

  • Standard
    12 pages
    English language
    sale 15% off

ISO 6134:2017 specifies requirements for two types of hoses and hose assemblies, low pressure with a maximum working pressure of 6 bar and high pressure with a maximum working pressure of 18 bar, made of rubber and hose fittings made of metal, designed to convey saturated steam and hot water condensate. Each type is divided into two classes having either an oil resistant or non-oil resistant cover. NOTE Information on the frequency of testing of hose assemblies in use and storage is given in Annex A and Annex B.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off

ISO 8033:2016 specifies methods for the determination of the adhesion between lining and reinforcement, between cover and reinforcement, between reinforcement layers, between cover and outer lamination (thin layer of material outside the cover for protection) and between lining and inner lamination (thin layer of material inside the lining to reduce permeation of fluid into the lining). It covers all bore sizes and the following types of hose construction: - woven textile fabric; - braided textile fabric; - knitted textile fabric; - circular-woven textile fabric; - textile spiral; - textile cord; - wire braid; - wire spiral; - hoses containing a supporting helix. Adequate adhesion between the various components of a hose is essential if it is to perform satisfactorily in service.

  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off

ISO 13775-2:2016 specifies test requirements and test methods for extruded thermoplastic tubing and hoses for use in petroleum-based-fuel lines in vehicles powered by internal-combustion engines.

  • Standard
    19 pages
    English language
    sale 15% off
  • Standard
    19 pages
    English language
    sale 15% off

ISO 4641:2016 specifies the minimum requirements for textile-reinforced, smooth-bore rubber water-suction and discharge hoses and hose assemblies. Three types of hoses and hose assemblies are specified according to their operating duty requirements, i.e. their ambient and water temperature ranges: - ambient temperatures: −25 °C to +70 °C; - water temperatures during operation: 0 °C to +70 °C.

  • Standard
    11 pages
    English language
    sale 15% off
  • Standard
    11 pages
    French language
    sale 15% off

ISO 6804:2016 specifies the requirements for three types of rubber or plastics inlet hoses and hose assemblies for washing-machines and dishwashers connected to the domestic water supply at a pressure not exceeding 1 MPa (10 bar). It is applicable to the following types of hose: - type 1: rubber hoses for unheated water supply (maximum temperature 70 °C); - type 2: rubber hoses for heated water supply (maximum temperature 90 °C); - type 3: plastics hoses for unheated water supply (maximum temperature 60 °C). There may be national requirements for hose fittings and hoses conveying drinking water which must be complied with.

  • Standard
    13 pages
    English language
    sale 15% off

ISO 8331:2016 sets out recommendations designed to maintain rubber and plastics hoses and hose assemblies, prior to use, in a condition as close as possible to the condition they were in when they were received and to obtain the expected service life. NOTE It is intended that this document be used in conjunction with any applicable national statutory regulations.

  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off

ISO 7751:2016 specifies ratios of proof pressure and minimum burst pressure to maximum working pressure for various categories of hose service.

  • Standard
    3 pages
    English language
    sale 15% off
  • Standard
    3 pages
    French language
    sale 15% off

ISO 1401:2016 specifies requirements for three types of flexible rubber hose for pressure spraying of agricultural chemicals and/or fertilizer products within a temperature range of ?10 °C to +60 °C.

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off

ISO 2398:2016 specifies the requirements for three types, three classes and two categories of textile-reinforced rubber hose for compressed air, up to a maximum working pressure of 25 bar with an operating-temperature range of −40 °C to +70 °C, depending on the type and category.

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    9 pages
    French language
    sale 15% off

ISO 4081:2016 specifies the requirements for straight or pre-formed rubber hoses and tubing for use in pressurized or unpressurized cooling circuits containing 1,2-ethanediol-based coolants in internal-combustion engines for vehicles with an unladen mass (as defined in ISO 1176) of 3,5 t or less. In addition, this specification may also be applied as a classification system to enable original equipment manufacturers (OEMs) to detail a "line call-out" of tests for specific applications where these are not covered by the main types specified (see example in Annex D). In this case, the hose or tubing would not carry any marking showing this ISO specification number but may detail the OEM's own identification markings as shown on their part drawings.

  • Standard
    15 pages
    English language
    sale 15% off

ISO 7326:2016 specifies five methods for determining the ozone resistance of the outer covers of hoses: - method 1, for bore sizes up to and including 25 mm, carried out on the hose itself; - method 2, for bore sizes greater than 25 mm, carried out on a test piece from the hose wall; - method 3, for bore sizes greater than 25 mm, carried out on a test piece from the cover; - method 4, for all bore sizes, carried out on the hose itself; - method 5, for all bore sizes, carried out on hoses that are expandable, for example textile-reinforced hoses. NOTE For hoses with built-in fittings from which it is not possible to take test pieces, the ozone resistance can be assessed on slabs in accordance with ISO 1431‑1, using test sheets of the appropriate polymeric compound vulcanized to the same degree.

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off

ISO 5774:2016 specifies the requirements for four types of flexible thermoplastic hose, textile reinforced, for compressed-air applications in the temperature range from −10 °C to +60 °C. The four types are classified as light service for a maximum working pressure of 7 bar at 23 °C and 4,5 bar at 60 °C, medium service for a maximum working pressure of 10 bar at 23 °C and 6,5 bar at 60 °C, heavy service for a maximum working pressure of 16 bar at 23 °C and 11 bar at 60 °C, and heavy service for use in mining for a maximum working pressure of 25 bar at 23 °C and 13 bar at 60 °C.

  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off