CISPR 24:2010 applies to information technology equipment (ITE) as defined in CISPR 22. The object of this publication is to establish requirements that will provide an adequate level of intrinsic immunity so that the equipment will operate as intended in its environment. The publication defines the immunity test requirements for equipment within its scope in relation to continuous and transient conducted and radiated disturbances, including electrostatic discharges (ESD). Procedures are defined for the measurement of ITE and limits are specified which are developed for ITE within the frequency range from 0 Hz to 400 GHz. For exceptional environmental conditions, special mitigation measures may be required. Owing to testing and performance assessment considerations, some tests are specified in defined frequency bands or at selected frequencies. Equipment which fulfils the requirements at these frequencies is deemed to fulfil the requirements in the entire frequency range from 0 Hz to 400 GHz for electromagnetic phenomena. The test requirements are specified for each port considered. This second edition cancels and replaces the first edition published in 1997, and its Amendments 1(2001) and 2(2002). It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- dated references updated;
- option of using a 4 % step size for continuous conducted immunity test deleted;
- revision of Annex A for telephony equipment including methodology for measuring the demodulation from a speaker/hands free device;
- inclusion of new annex related to DSL equipment. The contents of the corrigendum of June 2011 have been included in this copy.

  • Standard
    92 pages
    English and French language
    sale 15% off

Applies to television broadcast receivers, sound broadcast receivers and associated equipment intended for use in the residential, commercial and light industrial environment. Describes the methods of measurement and specified limits applicable to sound and television receivers and to associated equipment with regard to their immunity characteristics to disturbing signals. This standard is also applicable to the immunity of outdoor units of direct to home (DTH) satellite receiving systems for individual reception. Immunity requirements are given in the frequency range 0 Hz to 400 GHz. Radio-frequency tests outside the specified frequency bands or concerning other phenomena than given in this standard are not required. The objective of this standard is to define the immunity test requirements for equipment defined in the scope in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges. These test requirements represent essential electromagnetic immunity requirements. Test requirements are specified for each port (enclosure or connector) considered. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included: - residential properties, e.g. houses, apartments, etc.; - retail outlets, e.g. shops, supermarkets, etc.; - business premises, e.g. offices, banks, etc.; - areas of public entertainment, e.g. cinemas, public bars, dance halls, etc.; - outdoor locations, e.g. petrol stations, car parks, amusement and sports centres, etc.; - light-industrial locations e.g. workshops, laboratories, service centres, etc.; - car and boat. Locations which are characterized by their mains power being supplied directly at low voltage from the public mains are considered to be residential, commercial or light industrial.

  • Standard
    175 pages
    English and French language
    sale 15% off

CISPR TR 29:2020 is available as CISPR TR 29:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
CISPR TR 29:2020, which is a technical report, describes the algorithms used for objective picture assessment in immunity tests of analogue and digital TV broadcast receivers and associated equipment. The algorithms used were developed on the basis of the specifications originally included in Annex K of CISPR 20:2002/AMD2:2004, the later edition of which has been replaced by CISPR 35:2016. The method of objective picture assessment described in that annex employs the same interference mechanism and is based on the same wanted signal definition as specified in CISPR 35 for subjective picture assessment. Objective picture assessment, therefore, constitutes an alternative to the subjective method and offers the advantage of direct correlation to the subjective method. This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- update of the references, and
- editorial improvements.

  • Technical report
    12 pages
    English language
    sale 15% off

Gives requirements for flexible polyester (PETP) films coated on one side or both with polyester, acrylic or epoxide type adhesive for use in the fabrication of flexible printed wring.[
]Films coated on only one side are used as a coverlay or covercoat in the fabrication of flexible printed wiring. This coverlay or covercoat is also used to provide local support to areas subjected to mechanical or environmental stress.[
]Films coated on both sides are used as bonding films in the fabrication of printed boards.

  • Standard
    91 pages
    English and French language
    sale 15% off

CISPR 35:2016 applies to multimedia equipment (MME) having a rated AC or DC supply voltage not exceeding 600 V. The objectives of this document are:
- to establish requirements which provide an adequate level of intrinsic immunity so that the MME will operate as intended in its environment in the frequency range 0 kHz to 400 GHz; and
- to specify procedures to ensure the reproducibility of tests and the repeatability of results.

  • Standard
    165 pages
    English and French language
    sale 15% off

CISPR 32:2015 is available as CISPR 32:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
CISPR 32:2015 applies to multimedia equipment (MME) as defined in 3.1.24 and having a rated r.m.s. AC or DC supply voltage not exceeding 600 V. This publication covers two classes of MME (Class A and Class B). The MME classes are specified in Clause 4. The objectives of this publication are:
1) to establish requirements which provide an adequate level of protection of the radio spectrum, allowing radio services to operate as intended in the frequency range 9 kHz to 400 GHz;
2) to specify procedures to ensure the reproducibility of measurement and the repeatability of results.
This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. The contents of the corrigendum of June 2016 have been included in this copy.

  • Standard
    209 pages
    English and French language
    sale 15% off