Multi-element metallic cables used in analogue and digital communication and control - Part 1: Generic specification

When used together with EN 50290 and EN 50289, this European Standard covers cables for instrumentation, inter-connection of equipment and information technology cabling applications. Cables for information technology cabling systems, covered by this and the sectional specification standards in the EN 50288 series are suitable for use in digital and analogue data systems meeting the requirements, for example, of EN 50090-2-1, EN 50090-3-1, EN 50098-1, EN 50098-2 and EN 50173. Unless otherwise specified, all cables covered by this European Standard may be subjected to voltages greater than 50 V a.c or 75 V d.c. but not more than 300 V a.c. or 450 V d.c. and shall meet the essential requirements of the low voltage directive. Due to current limitation related to the conductor cross sectional area, they are not intended for direct connection to mains electricity supply. The maximum current rating per conductor is as stipulated in Table B.1 unless otherwise specified in the relevant sectional specification. IDCs are only designed for copper or metal coated copper. Cabling elements as defined in 4.3 of this European Standard may be incorporated in hybrid construction cables together with coaxial or optical fibre cabling elements.

Mehradrige metallische Daten- und Kontrollkabel für analoge und digitale Übertragung - Teil 1: Fachgrundspezifikation

Câbles métalliques à éléments multiples utilisés pour les transmissions et les commandes analogiques et numériques - Partie 1: Spécification générique

La présente Norme européenne, utilisée avec les EN 50289 et EN 50290, s'applique aux câbles pour les applications de câblage d'instrumentation, d’interconnexions d’équipements et de technologies de l'information.
Les câbles pour les systèmes de câblage propres aux technologies de l'information qui sont couverts par la présente norme ainsi que les normes de spécifications intermédiaires de la série EN 50288 sont adaptés pour une utilisation dans les systèmes de transmission de données numériques et analogiques conformes aux exigences, par exemple, des EN 50090-2-1, EN 50090-3-1, EN 50098-1, EN 50098-2 et EN 50173.
Sauf indication contraire, tous les câbles couverts par la présente norme européenne sont soumis à des tensions supérieures à 50 V c.a. ou 75 V c.c. mais sans dépasser 300 V c.a. ou 450 V c.c., et ils doivent répondre aux exigences essentielles de la Directive Basse Tension. Ils ne sont pas destinés à être utilisés pour une connexion directe au réseau d'alimentation électrique en raison du courant limité lié à la section des conducteurs. Le courant maximal assigné par conducteur est celle stipulée dans le Tableau B.1, sauf spécification contraire de la spécification particulière correspondante. Les IDC sont uniquement conçus pour les conducteurs en cuivre ou en métal cuivré.
Les éléments de câblage définis en 4.3 de la présente norme européenne peuvent être incorporés dans les câbles hybrides avec des éléments de câblage coaxiaux ou à fibres optiques.

Večelementni kovinski kabli za analogne in digitalne komunikacije in krmiljenje - 1. del: Rodovna specifikacija

Ko se ta evropski standard uporablja skupaj s standardoma EN 50290 in EN 50289, zajema kable za instrumente, kable za povezavo opreme in kable za uporabo v informacijski tehnologiji. Kabli za sisteme okabljenja informacijskih tehnologij, ki so vključeni v ta standard in v standarde področne specifikacije iz serije EN 50288, so primerni za uporabo v digitalnih in analognih podatkovnih sistemih, ki npr. ustrezajo zahtevam standardov EN 50090-2-1, EN 50090-3-1, EN 50098-1, EN 50098-2 in EN 50173. Razen če ni navedeno drugače, so lahko kabli, zajeti v tem evropskem standardu, izpostavljeni napetostim od 50 do 300 V izmenične napetosti ali od 75 do 450 V enosmerne napetosti in morajo biti skladni z bistvenimi zahtevami direktive o nizki napetosti. Zaradi trenutne omejitve, ki velja za prerez vodnika, niso namenjeni za neposredno povezavo z glavnim virom elektrike. Največji tok na prevodnik je določen v preglednici B.1, razen če je v ustrezni področni specifikaciji navedeno drugače. IDC-ji so namenjeni le za baker ali baker, prevlečen s kovino. Elemente za okablenje, kot so določeni v členu 4.3 tega evropskega standarda, je mogoče vključiti v hibridne konstrukcijske kable skupaj s koaksialnimi kabli ali kabli za optična vlakna.

General Information

Status
Published
Public Enquiry End Date
28-Mar-2012
Publication Date
10-Sep-2013
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
29-Aug-2013
Due Date
03-Nov-2013
Completion Date
11-Sep-2013

Relations

Buy Standard

Standard
EN 50288-1:2013
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50288-1:2013
01-oktober-2013
9HþHOHPHQWQLNRYLQVNLNDEOL]DDQDORJQHLQGLJLWDOQHNRPXQLNDFLMHLQNUPLOMHQMH
GHO5RGRYQDVSHFLILNDFLMD
Multi-element metallic cables used in analogue and digital communication and control -
Part 1: Generic specification
Mehradrige metallische Daten- und Kontrollkabel für analoge und digitale Übertragung -
Teil 1: Fachgrundspezifikation
Câbles métalliques à éléments multiples utilisés pour les transmissions et les
commandes analogiques et numériques - Partie 1: Spécification générique
Ta slovenski standard je istoveten z: EN 50288-1:2013
ICS:
33.120.20 äLFHLQVLPHWULþQLNDEOL Wires and symmetrical
cables
SIST EN 50288-1:2013 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 50288-1:2013

---------------------- Page: 2 ----------------------

SIST EN 50288-1:2013

EUROPEAN STANDARD
EN 50288-1

NORME EUROPÉENNE
May 2013
EUROPÄISCHE NORM

ICS 33.120.10 Supersedes EN 50288-1:2003


English version


Multi-element metallic cables used in analogue and digital communication
and control -
Part 1: Generic specification



Câbles métalliques à éléments multiples Mehradrige metallische Daten- und
utilisés pour les transmissions et les Kontrollkabel für analoge und digitale
commandes analogiques et numériques - Übertragung -
Partie 1: Spécification générique Teil 1: Fachgrundspezifikation






This European Standard was approved by CENELEC on 2013-03-18. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50288-1:2013 E

---------------------- Page: 3 ----------------------

SIST EN 50288-1:2013
EN 50288-1:2013 - 2 -

Contents
Page
Foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and Definitions . 4
4 Requirements for cable construction . 6
4.1 Conductors . 6
4.2 Insulation . 6
4.3 Cable elements . 6
4.4 Identification of cabling elements . 7
4.5 Screening of cabling elements . 7
4.7 Filling compounds . 7
4.8 Interstitial fillers . 8
4.9 Screening of the cable core . 8
4.10 Moisture barriers . 8
4.11 Protective wrappings . 8
4.12 Sheath . 8
4.13 Bedding layers for metallic protection . 8
4.14 Metallic protection . 8
4.15 Integral suspension strand . 9
4.16 Oversheath . 9
4.17 Fauna protection . 9
4.18 Chemical and /or environmental protection . 9
5 Test methods for completed cables . 9
5.1 Electrical test methods . 10
5.2 Mechanical test methods . 11
5.3 Environmental test methods . 12
5.4 Fire performance test methods . 12
Annex A (informative) ELFEXT re-classification to ACR-F . 16
Annex B (informative) MICE Table . 14

---------------------- Page: 4 ----------------------

SIST EN 50288-1:2013
- 3 - EN 50288-1:2013
Foreword
This document (EN 50288-1:2013) has been prepared by CLC/SC 46XC "Multicore, Multipair
and Quad Data communication cables," of CLC/TC 46X, "Communication cables".
The following dates are fixed:
• latest date by which this document has
(dop) 2014-03-18
to be implemented at national level by
publication of an identical national standard
or by endorsement
• latest date by which the national
(dow) 2016-03-18
standards conflicting with this document
have to be withdrawn
This document supersedes EN 50288-1:2003.
EN 50288-1:2013 includes the following significant technical changes with respect to
EN 50288-1:2003:
- the addition of the MICE table;
- a number minor corrections and updating of references;
- the re-classification of ‘ELFEXT’ to ‘ACR-F’.
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying
any or all such patent rights.
This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment
Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC).

---------------------- Page: 5 ----------------------

SIST EN 50288-1:2013
EN 50288-1:2013 - 4 -
1 Scope
When used together with EN 50290 and EN 50289, this European Standard covers cables for
instrumentation, inter-connection of equipment and information technology cabling
applications.
Cables for information technology cabling systems, covered by this and the sectional
specification standards in the EN 50288 series are suitable for use in digital and analogue
data systems meeting the requirements, for example, of EN 50090-2-1, EN 50090-3-1,
EN 50098-1, EN 50098-2 and EN 50173.
Unless otherwise specified, all cables covered by this European Standard may be subjected
to voltages greater than 50 V a.c or 75 V d.c. but not more than 300 V a.c. or 450 V d.c. and
shall meet the essential requirements of the low voltage directive. Due to current limitation
related to the conductor cross sectional area, they are not intended for direct connection to
mains electricity supply. The maximum current rating per conductor is as stipulated in Table
B.1 unless otherwise specified in the relevant sectional specification. IDCs are only designed
for copper or metal coated copper.
Cabling elements as defined in 4.3 of this European Standard may be incorporated in hybrid
construction cables together with coaxial or optical fibre cabling elements.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
EN 50173 series Information technology — Generic cabling systems
EN 50289 series Communication Cables — Specifications for tests methods
EN 50290-1-2 Communication cables — Part 1-2: Definitions
Communication cables — Part 2: Common design rules and
EN 50290-2 series
construction
Communication cables — Part 4-1: General considerations for the
EN 50290-4-1
use of cables – Environmental conditions and safety aspects
EN 60811 series Electrical and optical fibre cables —Test methods for non-metallic
materials.
EN ISO 6892-1 Metallic materials — Tensile testing — Part 1: Method of test at
room temperature (ISO 6892-1)
HD 402 S2 Standard colours for insulation for low-frequency cables and wires
(IEC 60304)
IEC 60028 International standard of resistance for copper

3 Terms and Definitions
For the purposes of this document, the terms and definitions given in EN 50290-1-2 and
EN 50173 series and the following apply:

---------------------- Page: 6 ----------------------

SIST EN 50288-1:2013
- 5 - EN 50288-1:2013
3.1
horizontal cable
cable suitable for connecting a floor distributor to a telecommunications outlet. It is suitable
for installation in ducts, trunking, suspended floors and ceiling cavities

3.2
building backbone cable
cable suitable for connecting a building distributor to a floor distributor and may also connect
floor distributors in the same building. It is suitable for horizontal installation or vertical
installation between floors provided the cable has adequate mechanical strength

Note 1 to entry: Horizontal cable as defined in 3.1 may also be used as building backbone cable
provided that it has adequate mechanical strength and fire performance characteristics.

3.3
work area cable
cable connecting the telecommunications outlet to the terminal equipment

3.4
patch cord cable
flexible cable unit or element with connector(s) used to establish connections on a patch
panel

Note 1 to entry: Work area cables, as defined in 3.3, may be used as patch cord cable in any
distributor of a generic building wiring system to interconnect with equipment or to cross-connect
between cabling systems.

3.5
campus backbone cable
cable suitable for connecting a campus distributor to a building distributor(s). If used outdoors
or for direct burial, it shall have adequate protection for its operational environment

3.6
equipment cable
cable connecting equipment to a distributor

3.7
instrumentation cable
multi-element cable suitable for connecting instruments and control systems. It may
incorporate screening, armouring and/or moisture barriers or environmental protection layers

3.8
MICE
classification system that describes the environment conditions that are local to a channel
based upon the following factors: mechanical (M), ingress (I), climatic and chemical (C) and
electromagnetic (E) (see Annex B)

[SOURCE: ISO/IEC/TR 29106]
3.9
Blank Detail Specification (BDS)
customer or manufacturer defined set of requirements that are agreed which are outside of
the scope in the sectional specifications. It may contain additional requirements where the
cable is not being installed in a normal office "environment"

Note 1 to entry: All sectional specifications for the EN 50288 series have a Blank Detail Specification
in Annex B.

---------------------- Page: 7 ----------------------

SIST EN 50288-1:2013
EN 50288-1:2013 - 6 -
4 Requirements for cable construction
4.1 Conductors
Conductors are to be solid or stranded copper as specified in the relevant EN 50288 sectional
specification.
The conductivity of copper conductors shall be in accordance with IEC 60028.
Stranded conductors shall consist of wires circular in section and assembled, without
insulation between them, by concentric stranding or bunching. As most of these cables are
used together with insulation displacement connecting devices (IDC), a maximum of seven
strands should be used.
The solid conductors or the individual wires of stranded conductor may be plain or metal-
coated.
There shall be no joint in the wire made subsequent to the last wire drawing operation.
Joints in individual strands of a stranded copper inner conductor shall be cold pressure welded,
brazed or silver soldered using a non acid flux such that the strand diameter shall not be increased.
No joint in an individual strand shall be within 0,3 m of a joint in any other individual strand.
The nominal conductor diameter is given in the relevant sectional specification. Other
diameters or stranded conductors are to be agreed between manufacturer and purchaser and
specified in Annex B of the relevant sectional specification.
4.2 Insulation
The choice of the insulating material shall take into account electrical and environmental
requirements.
The insulation material(s) shall meet the requirements of the relevant part or parts of
EN 50290-2, or otherwise as detailed in the relevant sectional specification. Conductor
insulation shall be composed of one or more suitable dielectric materials. The insulation may
be solid, cellular or composite (e.g. foam-skin).
The insulation shall be continuous, having a thickness as uniform as possible. When
required, the thickness of the insulation shall be measured in accordance with the method
specified in EN 60811-201.
The insulation shall be applied to fit closely to the conductor. When required, the stripping
properties of the insulation shall be checked in accordance with the method specified in
EN 50289-3-17. When not used with IDC termination, it shall be possible to strip the
insulation from the conductor easily and without visible damage to the conductor, its coating,
or the insulation remaining on the conductor.
4.3 Cable elements
The cable element is
- a single insulated wire, or
- a pair consisting of two insulated conductors twisted together and designa
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.