This document:
-   specifies methods for the measurement of airborne and structure-borne sound produced in waste water and rain water installations under laboratory conditions;
-   defines the expression of the results.
It is applicable to waste water piping systems and parts thereof, but not to the actual sources of the wastewater, e.g. lavatories, toilets and bathtubs or any active units. It applies to pipes with natural ventilation and made of any common material in commonly used diameters (up to 150 mm).
The results obtained can be used for the comparison of products and materials. It may serve in estimating the behaviour of waste water systems in a building under certain conditions. Nevertheless, this standard does not provide a normalized procedure for calculating the acoustical properties of such installations in a building.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document:
-   specifies methods for the measurement of airborne and structure-borne sound produced in waste water and rain water installations under laboratory conditions;
-   defines the expression of the results.
It is applicable to waste water piping systems and parts thereof, but not to the actual sources of the wastewater, e.g. lavatories, toilets and bathtubs or any active units. It applies to pipes with natural ventilation and made of any common material in commonly used diameters (up to 150 mm).
The results obtained can be used for the comparison of products and materials. It may serve in estimating the behaviour of waste water systems in a building under certain conditions. Nevertheless, this standard does not provide a normalized procedure for calculating the acoustical properties of such installations in a building.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the mounting and operating conditions to be used for in-line valves and
appliances which control the flow, pressure or temperature of the water in water supply installations,
when measuring noise emission resulting from water flow.
It is applicable to in-line valves and appliances of maximum nominal size DN 32 and to systems in which
the maximum water flow rate does not exceed 1,6 l/s.
NOTE See ISO 6708; DN is the symbol for “nominal size”. The number of the nominal size is loosely related to
the inside diameter (in millimetres) of the in-tine valves and appliances.
The procedures described are for general use for all types of in-line valves of conventional design.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 3822-3:2018 specifies the mounting and operating conditions to be used for in-line valves and appliances which control the flow, pressure or temperature of the water in water supply installations, when measuring noise emission resulting from water flow.
ISO 3822-3:2018 is applicable to in-line valves and appliances of maximum nominal size DN 32 and to systems in which the maximum water flow rate does not exceed 1,6 l/s.
NOTE See ISO 6708; DN is the symbol for "nominal size". The number of the nominal size is loosely related to the inside diameter (in millimetres) of the in-tine valves and appliances.
The procedures described are for general use for all types of in-line valves of conventional design.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 10140 specifies test requirements for building elements and products, including
detailed requirements for preparation, mounting, operating and test conditions, as well as applicable
quantities and additional test information for reporting. The general procedures for airborne and
impact sound insulation measurements are given in ISO 10140-2 and ISO 10140-3, respectively.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies reference values used in acoustics, in order to establish a uniform
basis for the expression of acoustical and vibratory levels.
The reference values are mandatory for use in acoustics for sounds in air and other gases, sounds in
water and other liquids, and for structure-borne sound, but can also be used in other applications.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 1683:2015 specifies reference values used in acoustics, in order to establish a uniform basis for the expression of acoustical and vibratory levels.
The reference values are mandatory for use in acoustics for sounds in air and other gases, sounds in water and other liquids, and for structure-borne sound, but can also be used in other applications.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The standard specifies the mounting and operating conditions to be used for draw-off taps when measuring noise emission resulting from water flow. It applies to complete draw-off tap assemblies, including any component normally supplied with the taps operating in a range of flow pressure between 0,1 and 0,5 MPa

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN ISO 3822 specifies the mounting and operating conditions to be used for a number of appliances which cannot be regarded as draw-off or in-line valves, when measuring the noise emission resulting from water flow.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN ISO 3822 specifies a method of measurement, in the laboratory, of the noise emission resulting from the flow of water through appliances and equipment used in water supply installations. The items covered include draw-off taps, in-line valves and special appliances, for example pressure reducers and water-heating appliances, all of which are hereafter referred to as "appliances". The method specified makes it possible to obtain comparable results of measurements in different laboratories.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN ISO 3822 specifies a method of measurement, in the laboratory, of the noise emission resulting from the flow of water through appliances and equipment used in water supply installations. The items covered include draw-off taps, in-line valves and special appliances, for example pressure reducers and water-heating appliances, all of which are hereafter referred to as "appliances". The method specified makes it possible to obtain comparable results of measurements in different laboratories.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Gives the mounting and operating conditions to be used for a number of in-line valves and appliances, when measuring the noise emission resulting from water flow. Replaces the first edition.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Describes the mounting and operating conditions to be used for draw-off taps and mixing valves when measuring noise emmission resulting from water flow. Replaces the first edition, which has been technically revised.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 10140 specifies laboratory test facilities and equipment for sound insulation measurements of building elements, such as: - components and materials; - building elements; - technical elements (small building elements); - sound insulation improvement systems. It is applicable to laboratory test facilities with suppressed radiation from flanking elements and structural isolation between source and receiving rooms. This part of ISO 10140 specifies qualification procedures for use when commissioning a new test facility with equipment for sound insulation measurements. It is intended that these procedures be repeated periodically to ensure that there are no issues with the equipment and the test facility.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 10140 specifies laboratory test facilities and equipment for sound insulation measurements of building elements, such as: - components and materials; - building elements; - technical elements (small building elements); - sound insulation improvement systems. It is applicable to laboratory test facilities with suppressed radiation from flanking elements and structural isolation between source and receiving rooms. This part of ISO 10140 specifies qualification procedures for use when commissioning a new test facility with equipment for sound insulation measurements. It is intended that these procedures be repeated periodically to ensure that there are no issues with the equipment and the test facility.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 80000-8 gives names, symbols and definitions for quantities and units of acoustics. Where appropriate, conversion factors are also given.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 80000-8:2007 gives names, symbols and definitions for quantities and units of acoustics. Where appropriate, conversion factors are also given.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document:
-   specifies methods for the measurement of airborne and structure-borne sound produced in waste water and rain water installations under laboratory conditions;
-   defines the expression of the results.
It is applicable to waste water piping systems and parts thereof, but not to the actual sources of the wastewater, e.g. lavatories, toilets and bathtubs or any active units. It applies to pipes with natural ventilation and made of any common material in commonly used diameters (up to 150 mm).
The results obtained can be used for the comparison of products and materials. It may serve in estimating the behaviour of waste water systems in a building under certain conditions. Nevertheless, this standard does not provide a normalized procedure for calculating the acoustical properties of such installations in a building.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document:
-   specifies methods for the measurement of airborne and structure-borne sound produced in waste water and rain water installations under laboratory conditions;
-   defines the expression of the results.
It is applicable to waste water piping systems and parts thereof, but not to the actual sources of the wastewater, e.g. lavatories, toilets and bathtubs or any active units. It applies to pipes with natural ventilation and made of any common material in commonly used diameters (up to 150 mm).
The results obtained can be used for the comparison of products and materials. It may serve in estimating the behaviour of waste water systems in a building under certain conditions. Nevertheless, this standard does not provide a normalized procedure for calculating the acoustical properties of such installations in a building.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN ISO 3822 specifies the mounting and operating conditions to be used for on-line valves and appliances which control the flow, pressure or temperature of the water in water supply installations, when measuring noise emission resulting from water flow. It is applicable to in-line valves and appliances of maximum nominal size DN 32 and to systems in which the maximum water flow rate does not exceed 2 l/s. The procedures described are for general use for all types of in-line valves of conventional design.

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN ISO 3822 specifies the mounting and operating conditions to be used for on-line valves and appliances which control the flow, pressure or temperature of the water in water supply installations, when measuring noise emission resulting from water flow. It is applicable to in-line valves and appliances of maximum nominal size DN 32 and to systems in which the maximum water flow rate does not exceed 2 l/s. The procedures described are for general use for all types of in-line valves of conventional design.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN ISO 3822 specifies the mounting and operating conditions to be used for on-line valves and appliances which control the flow, pressure or temperature of the water in water supply installations, when measuring noise emission resulting from water flow. It is applicable to in-line valves and appliances of maximum nominal size DN 32 and to systems in which the maximum water flow rate does not exceed 2 l/s. The procedures described are for general use for all types of in-line valves of conventional design.

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Gives the mounting and operating conditions to be used for in-line valves and appliances, which control the flow, pressure or temperature of the water in water supply installations, when measuring the noise emission resulting from water flow. Replaces the first edition.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 10140 specifies test requirements for building elements and products, including detailed requirements for preparation, mounting, operating and test conditions, as well as applicable quantities and additional test information for reporting. The general procedures for airborne and impact sound insulation measurements are given in ISO 10140-2 and ISO 10140-3, respectively.

  • Amendment
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 10140 specifies test requirements for building elements and products, including detailed requirements for preparation, mounting, operating and test conditions, as well as applicable quantities and additional test information for reporting. The general procedures for airborne and impact sound insulation measurements are given in ISO 10140-2 and ISO 10140-3, respectively.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 10140-1:2016 specifies test requirements for building elements and products, including detailed requirements for preparation, mounting, operating and test conditions, as well as applicable quantities and additional test information for reporting. The general procedures for airborne and impact sound insulation measurements are given in ISO 10140-2 and ISO 10140-3, respectively.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2013-07-04 GVN: Text for // vote received in ISO/CS (see notification from 2013-07-03 in dataservice).
2012-09-07 GVN: Text for // enquiry received in ISO/CS (see notification from 2012-09-07 in dataservice).
2010-03-16 EMA: No consultancy required following e-mail sent from PM to dataservice on 2010-03-16.

  • Amendment
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 10140-1:2010 specifies test requirements for building elements and products, including detailed requirements for preparation, mounting, operating and test conditions, as well as applicable quantities and additional test information to be reported.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN ISO 140 specifies a laboratory method of measuring the airborne and impact sound insulation of an access floor with a plenum of defined height mounted below an acoustical barrier which separates two rooms of a specified test facility.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies reference values used in acoustics, in order to establish a uniform basis for the expression of acoustical and vibratory levels. The reference values are mandatory for use in acoustics for airborne and structure-borne sound, but may also be used in other applications.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 1683:2008 specifies reference values used in acoustics, in order to establish a uniform basis for the expression of acoustical and vibratory levels.
The reference values are mandatory for use in acoustics for airborne and structure-borne sound but may also be used in other applications.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2013-07-04 GVN: Text for // vote received in ISO/CS (see notification from 2013-07-03 in dataservice).
2012-09-07 GVN: Text for // enquiry received in ISO/CS (see notification from 2012-09-07 in dataservice)
2010-03-16 EMA: No consultancy required following e-mail sent from PM to dataservice on 2010-03-16.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The standard specifies a laboratory method of measuring impact noise transmission through floors by using a standard tapping machine.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Migrated from Progress Sheet (TC Comment) (2000-07-10): Resolution BTS1 21/92: parallel vote CEN/ISO ++ EN ISO 140-1 and -3 to -8 are a package and have as DOW 1997-06-30 (BTS1 17/94) ++ DOW for EN ISO 140-1, -3 to -8 will be 1998-12-31 (2nd ext. - BTS1 C 16/1997)

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Migrated from Progress Sheet (TC Comment) (2000-07-10): EN ISO 140-1 and -3 to -8 are a package and have as DOW 1997-06-30 (BTS1 17/94) ++ DOW for EN ISO 140-1, -3 to -8 will be 1998-12-31 (2nd ext. - BTS1 C 16/1997)

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 10140-5:2010 specifies laboratory test facilities and equipment for sound insulation measurements of building elements, such as components and materials, building elements, technical elements (small building elements) and sound insulation improvement systems.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The standard specifies a laboratory method of measuring impact noise transmission through floors by using a standard tapping machine.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Migrated from Progress Sheet (TC Comment) (2000-07-10): Resolution BTS1 21/92: parallel vote CEN/ISO ++ EN ISO 140-1 and -3 to -8 are a package and have as DOW 1997-06-30 (BTS1 17/94) ++ DOW for EN ISO 140-1, -3 to -8 will be 1998-12-31 (2nd ext. - BTS1 C 16/1997)

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Migrated from Progress Sheet (TC Comment) (2000-07-10): EN ISO 140-1 and -3 to -8 are a package and have as DOW 1997-06-30 (BTS1 17/94) ++ DOW for EN ISO 140-1, -3 to -8 will be 1998-12-31 (2nd ext. - BTS1 C 16/1997)

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN ISO 140 specifies a laboratory method of measuring the airborne and impact sound insulation of an access floor with a plenum of defined height mounted below an acoustical barrier which separates two rooms of a specified test facility.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for