This Technical Specification specifies a method for the determination of acrylamide in cereal-based products, potato-based products and coffee by gas-chromatography mass spectrometry (GC-MS).
The method has been single-laboratory validated via the analysis of spiked samples (French fries (uncooked), bread, water biscuit, infant cereal, biscuit, green coffee, roast coffee and instant coffee, ranging from 30 μg/kg to 1 500 μg/kg acrylamide.
The results from the single laboratory validation were obtained by a laboratory with significant experience in acrylamide analysis. In addition, this method has also been studied by inter laboratory trial via the analysis of samples containing incurred acrylamide, ranging from approximately 200 μg/kg to 2 000 μg/kg. Critical points of the method are identified in 7.5 and Clause 8.

  • Technical specification
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of melamine and cyanuric acid in foodstuffs with liquid chromatography in combination with tandem mass spectrometry. The method has been validated in an interlaboratory study via the analysis of spiked samples of milk based infant formula, soy based infant formula, milk powder, whole milk, soy milk and milk chocolate ranging from 0,71 mg/kg to 1,43 mg/kg for melamine and 0,57 mg/kg to 1,45 mg/kg for cyanuric acid. The limits of quantification (LOQ) for melamine and cyanuric acid in food are 0,05 mg/kg and 0,25 mg/kg, respectively. The upper limit of the working range is up to 10 mg/kg for melamine and up to 25 mg/kg for cyanuric acid.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of saturated and aromatic hydrocarbons (from C10 to C50) in vegetable fats and oils and foodstuff on basis of vegetable oils with online-HPLC-GC-FID [1], [2]. HPLC-GC-FID provides a highly efficient method for the determination of mineral oils in different foodstuffs [3].
The method can be used for the analysis of MOSH and/or MOAH. Mineral oil saturated hydrocarbons (MOSH) are paraffinic (open-chain, usually branched) and naphthenic (cyclic, alkylated) hydrocarbons, mineral oil aromatic hydrocarbons (MOAH) are aromatic mainly alkylated hydrocarbons.
The method has been tested in an interlaboratory study via the analysis of both naturally contaminated and spiked vegetable oil samples and mayonnaise and margarine samples, ranging from 4 mg/kg to 197 mg/kg for MOSH, and from 2 mg/kg to 51 mg/kg for MOAH.
The method has been proved suitable above 10 mg/kg on basis on the results of the interlaboratory tests.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a highly efficient method for the determination of saturated and aromatic hydrocarbons (from C10 to C50) in vegetable fats and oils and foodstuff on basis of vegetable oils for which it has been interlaboratory validated, with online-HPLC-GC-FID [1], [2] and [3]. This standard is not intended to be applied to other matrices.
The method can be used for the analysis of mineral oil saturated hydrocarbons (MOSH) and/or mineral oil aromatic hydrocarbons (MOAH).
The method has been tested in an interlaboratory study via the analysis of both naturally contaminated and spiked vegetable oil samples and mayonnaise and margarine samples, ranging from 4 mg/kg to 197 mg/kg for MOSH, and from 2 mg/kg to 51 mg/kg for MOAH.
According to the results of the interlaboratory studies, the method has been proven suitable for MOSH- and MOAH mass concentrations each above 10 mg/kg.
In case of suspected interferences from natural sources, the mineral origin of the MOSH and MOAH fraction can be verified by examination of the pattern by GC-MS.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Specification specifies a method for the determination of acrylamide in cereal-based products, potato-based products and coffee by gas-chromatography mass spectrometry (GC-MS).
The method has been single-laboratory validated via the analysis of spiked samples (French fries (uncooked), bread, water biscuit, infant cereal, biscuit, green coffee, roast coffee and instant coffee), ranging from 30 μg/kg to 1 500 μg/kg acrylamide.
The results from the single laboratory validation were obtained by a laboratory with significant experience in acrylamide analysis. In addition, this method has also been studied by inter laboratory trial via the analysis of samples containing incurred acrylamide, ranging from approximately 200 μg/kg to 2 000 μg/kg. Critical points of the method are identified in 7.5 and Clause 8.

  • Technical specification
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a gas chromatographic method using mass spectrometric detection for the determination of ethyl carbamate (EC) in stone fruit spirits, fruit marc spirits and other spirit drinks.
The method has been validated in an interlaboratory study for stone fruit spirits and fruit liqueurs, at levels ranging from 0,253 mg/l to 1,11 mg/l. However, linearity of the instrument response was proven for the concentration range 0,10 mg/l to 4,0 mg/l (simplified method) and 0,025 mg/l to 3,0 mg/l (procedure including sample clean-up), respectively.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard shall specify a method of analysis for the determination of benzene in soft drinks, juices and baby food. The method should preferably make use of the HS GC-MS technique. The method shall be inter-laboratory validated, in accordance with ISO 5725 or with AOAC International Guidelines for collaborative study procedures to validate characteristics of a method of analysis, using test materials consisting of soft drinks, juices and baby food at appropriate levels.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of melamine and cyanuric acid in foodstuffs with liquid chromatography in combination with tandem mass spectrometry. The method has been validated in an interlaboratory study via the analysis of spiked samples of milk based infant formula, soy based infant formula, milk powder, whole milk, soy drink and milk chocolate ranging from 0,71 mg/kg to 1,43 mg/kg for melamine and 0,57 mg/kg to 1,45 mg/kg for cyanuric acid. The limits of quantification (LOQ) for melamine and cyanuric acid in food are 0,05 mg/kg and 0,25 mg/kg, respectively. The upper limit of the working range is up to 10 mg/kg for melamine and up to 25 mg/kg for cyanuric acid.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a gas chromatographic method using mass spectrometric detection for the determination of ethyl carbamate (EC) in stone fruit spirits, fruit marc spirits and other spirit drinks.
The method has been validated in an interlaboratory study for stone fruit spirits and fruit liqueurs, at levels ranging from 0,253 mg/l to 1,11 mg/l. However, linearity of the instrument response was proven for the concentration ranges 0,10 mg/l to 4,0 mg/l (simplified method) and 0,025 mg/l to 3,0 mg/l (procedure including sample clean-up), respectively.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of benzene in soft drinks, other beverages and vegetable-based infant foods, by headspace gas chromatography mass spectrometry (HS-GC-MS). The method has been validated in an interlaboratory study via the analysis of spiked samples of carbonated soft drink, still fruit-based drink, carbonated fruit-based drink, vegetable and fruit juice containing carrot, infant food vegetable based and infant food containing meat, ranging from 1,9 µg/kg to 18,6 µg/kg. However, linearity of the instrument response was proven for the concentration range from 0,5 µg/kg to 20 µg/kg. The limit of quantification (LOQ) depends on the instrument but can generally be expected to be in the range from 0,5 µg/kg to 1,0 µg/kg.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard gives the standardization framework of communication systems applicable to the exchange of data from metering devices to other devices within a mesh network.
This European Standard specifies how to interpret prEN 16836-2:2015 and prEN 16836-3:2015 which give a list of references to the ZigBee documents. This series is applicable to communications systems that involve messages and networking between a meter or multiple meters and other devices in a mesh network, such as in home displays (IHDs) and communications hubs. This European Standard allows routing between devices and also allows channel agility to avoid contention with other networks of the same type, or indeed networks of other types operating in the same frequency bands.
This European Standard is designed to support low power communications for devices such as gas and water meters which can make data from such devices available on the mesh network at any time through a proxy capability within a permanently powered device.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard gives the standardization framework of communication systems applicable to the exchange of data from metering devices to other devices within a mesh network.
This European Standard specifies how to interpret prEN 16836-2:2015 and prEN 16836-3:2015 which give a list of references to the ZigBee documents. This series is applicable to communications systems that involve messages and networking between a meter or multiple meters and other devices in a mesh network, such as in home displays (IHDs) and communications hubs. This European Standard allows routing between devices and also allows channel agility to avoid contention with other networks of the same type, or indeed networks of other types operating in the same frequency bands.
This European Standard is designed to support low power communications for devices such as gas and water meters which can make data from such devices available on the mesh network at any time through a proxy capability within a permanently powered device.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of furan in coffee and coffee products with headspace-gas chromatography-mass spectrometry (HS-GC-MS), see [1] and [2]. Coffee products in the scope of this method are extracts which have been spray-dried, agglomerated or freeze-dried. The method has been validated in an interlaboratory study via the analysis of naturally contaminated samples of spray-dried coffee, freeze-dried coffee and roasted coffee ranging from 263,8 µg/kg to 2 840,7 µg/kg.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of 4 of the 15+1 EU priority polycyclic aromatic hydrocarbons (PAHs), identified as target PAHs. They are benz[a]anthracene (BaA), benzo[a]pyrene (BaP), benzo[b]fluoranthene (BbF) and chrysene (CHR). The method allows their quantification in the presence of the other 12 EU priority PAHs (benzo[j]fluoranthene (BjF), cyclopenta[cd]pyrene (CPP), benzo[k]fluoranthene (BkF), dibenz[a,h]anthracene (DhA), benzo[c]fluorene (BcL), dibenzo[a,e]pyrene (DeP), benzo[ghi]perylene (BgP), dibenzo[a,h]pyrene (DhP), dibenzo[a,i]pyrene (DiP), dibenzo[a,l]pyrene (DlP), indeno[1,2,3-cd]pyrene (IcP), 5-methylchrysene (5MC)) in extruded wheat flour, smoked fish, dry infant formula, sausage meat, freeze dried mussels, edible oil and wheat flour, by gas-chromatography mass-spectrometry (GC-MS). The extraction of PAHs from solid samples is performed by pressurised liquid extraction (PLE). Soxhlet extraction may be applied as alternative to PLE. The sample cleanup is performed by applying the following techniques in the reported sequence: size exclusion chromatography (SEC), and solid phase extraction (SPE).
This method complies with the performance characteristics specified in Commission Regulation (EU) No 836/2011 (see [1]).
The method has been validated in an interlaboratory study via the analysis of both naturally contaminated and spiked samples, ranging from 0,5 µg/kg to 11,9 µg/kg. However, linearity of the instrument response was proven for the concentration range 0,5 µg/kg to 20 µg/kg.
For the determination of PAHs in edible fats and oils, two other CEN standards are also available, EN ISO 22959 and EN ISO 15753, for more information see [2] and [3].

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the determination of acrylamide in bakery ware such as bread, toasted bread, crisp bread, butter cookies, and biscuits, as well as potato products such as potato chips, potato crisps, and potato pan cake and roasted coffee, by liquid chromatography in combination with electrospray ionisation and tandem mass spectrometry (LC-ESI-MS/MS). This method has been validated in an interlaboratory study via the analysis of both naturally contaminated and spiked samples, ranging from 14,3 µg/kg tot 9 083 µg/kg. It was developed at the Swedish National Food Administration and validated in a study organized by the Directorate General Joint Research Centre (DG JRC), Swedish National Food Administration and the Nordic Committee on Food Analysis (NMKL), see [1] and [2].
The limit of quantification (LOQ) depends on the type of instrument used and on the actual performance of the instrument. The majority of the laboratories participating in the validation study was able to determine acrylamide in a butter cookie sample at a level of 14,3 µg/kg. The validation by interlaboratory study showed that it can be expected to be in the range below 15 µg/kg and 30 µg/kg.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of 4 of the 16 EU priority polycyclic aromatic hydrocarbons (PAHs), identified as target PAHs. They are benz[a]anthracene (BaA), benzo[a]pyrene (BaP), benzo[b]fluoranthene (BbF) and chrysene (CHR). The method allows their quantification in the presence of the other 12 EU priority PAHs (benzo[j]fluoranthene (BjF), cyclopenta[cd]pyrene (CPP), benzo[k]fluoranthene (BkF), dibenz[a,h]anthracene (DhA), benzo[c]fluorene (BcL), dibenzo[a,e]pyrene (DeP), benzo[ghi]perylene (BgP), dibenzo[a,h]pyrene (DhP), dibenzo[a,i]pyrene (DiP), dibenzo[a,l]pyrene (DlP), indeno[1,2,3-cd]pyrene (IcP), 5-methylchrysene (5MC)) in extruded wheat flour, smoked fish, dry infant formula, sausage meat, freeze-dried mussels, edible oil and wheat flour, by gas-chromatography mass-spectrometry (GC-MS). The extraction of PAHs from solid samples is performed by pressurized liquid extraction (PLE). Soxhlet extraction was applied by some participants in the validation study by collaborative trial as alternative to PLE. The sample cleanup is performed by applying the following techniques in the reported sequence: size exclusion chromatography (SEC), and solid phase extraction (SPE).
This method complies with the performance characteristics specified in Commission Regulation (EU) No 836/2011 (see [1]). In particular the specifications for the limit of detection (LOD) and of the limit of quantification (LOQ) (0,30 µg/kg and 0,90 µg/kg respectively) were met.
The method has been validated in an interlaboratory study via the analysis of both naturally contaminated and spiked samples, ranging from 0,5 µg/kg to 11,9 µg/kg. However, linearity of the instrument response was proven for the concentration range 0,5 µg/kg to 20 µg/kg.
For the determination of PAHs in edible fats and oils, two other CEN standards are also available, EN ISO 22959 and EN ISO 15753, for more information see [2] and [3].

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of acrylamide in bakery ware such as bread, toasted bread, crisp bread, butter cookies, and biscuits, as well as potato products such as potato chips, potato crisps, and potato pan cake and roasted coffee, by liquid chromatography in combination with electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS). This method has been validated in an interlaboratory study via the analysis of both naturally contaminated and spiked samples, ranging from 14,3 µg/kg to 9 083 µg/kg. It was developed at the Swedish National Food Administration and validated in a study organized by the Directorate General Joint Research Centre (DG JRC), Swedish National Food Administration and the Nordic Committee on Food Analysis (NMKL), see [1] and [2].
The limit of quantification (LOQ) depends on the type of instrument used and on the actual performance of the instrument. The majority of the laboratories participating in the validation study were able to determine acrylamide in a butter cookie sample at a level of 14,3 µg/kg. Thus, the validation by interlaboratory study showed that LOQ can be expected to be in the range between below 15 µg/kg and 30 µg/kg.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of furan in coffee and coffee products with headspace-gas chromatography-mass spectrometry (HS-GC-MS), see [1] and [2]. Coffee products in the scope of this method are extracts which have been spray-dried, agglomerated or freeze-dried. The method has been validated in an interlaboratory study via the analysis of naturally contaminated samples of spray-dried coffee, freeze-dried coffee and ground roasted coffee ranging from 264 µg/kg to 2 840 µg/kg.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

CEN/TS 16621 specifies a method for the determination of benzo[a]pyrene (BaP) plus benz[a]anthracene (BaA), benzo[b]fluoranthene (BbF) and chrysene (CHR) in several food matrices. The method is based on size exclusion chromatography (SEC) cleanup, followed by quantification with high performance liquid chromatography (HPLC) with programmable fluorescence detection. This method has been in-house validated via the analysis of spiked samples of edible olive oil, fresh mussels, smoked fish, smoked meat products, processed cereal-based foods for young children, infant formulae, chocolate and food supplements (isoflavones) at levels ranging from 0,25 μg/kg to 1,00 μg/kg and from 4,95 μg/kg to 23,53 μg/kg, depending on the Polycyclic Aromatic Hydrocarbon (PAH) or the matrix. This method complies with the performance characteristics specified for BaP, BaA, BbF and CHR in current legislation [3]. The method has been shown to be applicable to a variety of additional matrices as meat products, fresh fish, paprika, roasted coffee, bread, herbs, breakfast cereals, beer, sunflower oil, olives and fried tomato, with a limit of quantification below 0,5 μg/kg. In addition, the method was tested in-house and shown to be applicable also for the quantification of the other 12 PAHs of the 15+1 EU priority PAHs set (benzo[c]fluorene (BcL), benzo[j]fluoranthene (BjF), benzo[k]fluoranthene (BkF), cyclopenta[cd]pyrene (CPP), dibenz[a,h]anthracene (DhA), dibenzo[a,e]pyrene (DeP), benzo[ghi]perylene (BgP), dibenzo[a,h]pyrene (DhP), dibenzo[a,i]pyrene (DiP), dibenzo[a,l]pyrene (DlP), indeno[1,2,3-cd]pyrene (IcP), 5-methylchrysene (5MC)) in all matrices listed above and at similar level ranges, except for CPP, where a UV detection had to be used with limits of quantification above 8 μg/kg. For the determination of PAHs in edible fats and oils, two other standards are also available, EN ISO 22959 and EN ISO 15753 (see [1] and [2]).

  • Technical specification
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Specification specifies a method for the determination of benzo[a]pyrene (BaP) plus benz[a]anthracene (BaA), benzo[b]fluoranthene (BbF) and chrysene (CHR) in several food matrices. The method is based on size exclusion chromatography (SEC) cleanup, followed by quantification with high performance liquid chromatography (HPLC) with programmable fluorescence detection. This method has been in-house validated via the analysis of spiked samples of edible olive oil, fresh mussels, smoked fish, smoked meat products, processed cereal-based foods for young children, infant formulae, chocolate and food supplements (isoflavones) at levels ranging from 0,25 μg/kg to 1,00 μg/kg and from 4,95 μg/kg to 23,53 µg/kg, depending on the Polycyclic Aromatic Hydrocarbon (PAH) or the matrix. This method complies with the performance characteristics specified for BaP, BaA, BbF and CHR in current legislation [3].
The method has been shown to be applicable to a variety of additional matrices as meat products, fresh fish, paprika, roasted coffee, bread, herbs, breakfast cereals, beer, sunflower oil, olives and fried tomato, with a limit of quantification below 0,5 µg/kg.
In addition, the method was tested in-house and shown to be applicable also for the quantification of the other 12 PAHs of the 15+1 EU priority PAHs set (benzo[c]fluorene (BcL), benzo[j]fluoranthene (BjF), benzo[k]fluoranthene (BkF), cyclopenta[cd]pyrene (CPP), dibenz[a,h]anthracene (DhA), dibenzo[a,e]pyrene (DeP), benzo[ghi]perylene (BgP), dibenzo[a,h]pyrene (DhP), dibenzo[a,i]pyrene (DiP), dibenzo[a,l]pyrene (DlP), indeno[1,2,3-cd]pyrene (IcP), 5-methylchrysene (5MC)) in all matrices listed above and at similar level ranges, except for CPP, where a UV detection had to be used with limits of quantification above 8 µg/kg.
For the determination of PAHs in edible fats and oils, two other standards are also available, EN ISO 22959 and EN ISO 15753 (see [1] and [2]).

  • Technical specification
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies methods for the determination of acrylamide in coffee and coffee products by extraction with water, clean-up by solid-phase extraction and determination by HPLC-MS/MS and GC-MS. It was validated in a method validation study on roasted coffee, soluble coffee, coffee substitutes and coffee products with ranges from 53 μg/kg to 612,1 μg/kg.

  • Draft
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies methods for the determination of acrylamide in coffee and coffee products by extraction with water, clean-up by solid-phase extraction and determination by HPLC-MS/MS and GC-MS. It was validated in a method validation study on roasted coffee, soluble coffee, coffee substitutes and coffee products with ranges from 53 μg/kg to 612,1 μg/kg.

  • Draft
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day