This document specifies minimum requirements for design and testing of contents gauges, which are directly connected to LPG transportable pressure vessels, LPG drums, LPG cylinders and static LPG pressure vessels above 0,5 l water capacity excluding those used for automotive containers.
This document includes minimum requirements for the safe interchangeability of telemetry equipment, which is either integral in or additional to the contents gauge.
This document does not apply to refineries or other process plants.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

DOP of 12 months!
2017-03-29 FJD - No xml version as the mother standard EN 1993-4-2:2007 was not edited as an xml deliverable.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits based on the detection of the presence of liquid and/or vapour in interstitial spaces, leakage containments or monitoring wells. The kits are usually composed by:
- sensing device(s);
- evaluation device;
- alarm device.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the general principles for leak detection systems for use with double-skin tanks, single-skin tanks and pipework designed for water polluting fluids.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits based on the drop of the liquid level in the leak detection liquid reservoir. Leak detection kits are intended to be used with double skin, underground or above ground, non-pressurized, tanks designed for water polluting liquids.
The liquid leak detection kits are usually composed of:
- sensing device (liquid sensor);
- evaluation device;
- alarm device.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits (leak detector) based on the measurement of pressure change. Leak detection kits are intended to be used with double skin, underground or above ground, pressurized or non-pressurized, tanks or pipework designed for water polluting liquids/fluids. The kits are usually composed of:
-   measuring device;
-   evaluation device;
-   alarm device;
-   pressure generator;
-   pressure relief device;
-   liquid stop device;
-   condensate trap.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard gives requirements and the corresponding test/assessment methods applicable to leak detection lining kits and leak detection jacket kits. Leak detection lining kits and leak detection jackets kits intended to be used as post-installed to create an interstitial space or leakage containment in single skin underground or above ground, non-pressurized, tanks designed for water polluting liquids. The kit has to be used only in conjunction with leak detection kits covered by prEN 13160-2 to prEN 13160-4.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for leak detection systems - class V for use with systems designed for fuels which are flammable, having a flash point up to but not exceeding 100 °C.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits (leak detector) based on the measurement of pressure change. Leak detection kits are intended to be used with double skin, underground or above ground, pressurized or non-pressurized, tanks or pipework designed for water polluting liquids/fluids. The kits are usually composed of:
- measuring device;
- evaluation device;
- alarm device;
- pressure generator;
- pressure relief device;
- liquid stop device;
- condensate trap.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard gives requirements and the corresponding test/assessment methods applicable to leak detection lining kits and leak detection jacket kits. Leak detection lining kits and leak detection jackets kits intended to be used as post-installed to create an interstitial space or leakage containment in single skin underground or above ground, non-pressurized, tanks designed for water polluting liquids. The kit has to be used only in conjunction with leak detection kits covered by prEN 13160-2 to prEN 13160-4.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits based on the detection of the presence of liquid and/or vapour in interstitial spaces, leakage containments or monitoring wells. The kits are usually composed by:
- sensing device(s);
- evaluation device;
- alarm device.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the general principles for leak detection systems for use with double-skin tanks, single-skin tanks and pipework designed for water polluting fluids.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for leak detection systems - class V for use with systems designed for fuels which are flammable, having a flash point up to but not exceeding 100 °C.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Complementary to Part 1. Varied general rules and additional detailed rules for the structural design of vertical above ground steel tanks for the storage of liquids.

  • Standard
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TC - Modifications in the E mother reference version in the Foreword, in Clauses 1, 2, 3, 4, 5, 7, 9 and 11, and in Annex A.
2013: Originator of XML version: first setup pilot of CCMC in 2012

  • Corrigendum
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

- Revised scope and deletion of inappropriate sections
- Quantitative definitions for consequence classes
- Toughness and corrosion requirements
- Structural issues for nozzles
- Wind rings and anchorage under wind

  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the general principles for leak detection systems for use with double-skin
tanks, single-skin tanks and pipework designed for water polluting fluids.

  • Draft
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for leak detection systems – class II for use with doubleskin
tanks designed for water polluting fluids.

  • Draft
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the general principles for leak detection systems for use with double-skin
tanks, single-skin tanks and pipework designed for water polluting fluids.

  • Draft
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies minimum requirements for design and testing of contents gauges, which are directly connected to transportable tanks, drums, cylinders and static LPG tanks above 0,5 l water capacity excluding those used for automotive containers. This European Standard does not apply to refineries or other process plants.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the general principles for leak detection systems for use with double-skin tanks, single-skin tanks and pipework designed for water polluting fluids.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the type test of the interstitial space and the general requirements and test methods for leak protecting linings and leak protecting jackets which are parts of leak detection systems.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class III for use in the interstitial space of double-skin systems or in leakage containments of single skin systems designed for water polluting fluids.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class I for use with double-skin systems, designed for water polluting fluids.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class II for use with double-skin systems designed for water polluting fluids.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class III for use in the interstitial space of double-skin systems or in leakage containments of single skin systems designed for water polluting fluids.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the type test of the interstitial space and the general requirements and test methods for leak protecting linings and leak protecting jackets which are parts of leak detection systems.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the general principles for leak detection systems for use with double-skin tanks, single-skin tanks and pipework designed for water polluting fluids.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class I for use with double-skin systems, designed for water polluting fluids.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class V for use with systems designed for fuels which are flammable having a flash point up to but not exceeding 100 °C.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for leak detection systems - class V for use with systems designed for fuels which are flammable having a flash point up to but not exceeding 100 °C.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Part 4.2 of Eurocode 3 provides principles and application rules for the structural design of vertical cylindrical above ground steel tanks for the storage of liquid products with the following characteristics: a) characteristic internal pressures not less than -100mbar and not more than 500mbar. b) design metal temperature in the range of -196°C to + 300°C. c) maximum design liquid level not higher than the top of the cylindrical shell.

  • Standard + National Annex and/or Foreword
    49 pages
    Foreword and/or annex in Slovenian language, body of the standard in English language
    sale 10% off
    e-Library read for
    1 day