This document describes radon-222 integrated measurement techniques with passive sampling. It gives indications for determining the average activity concentration of the radon-222 in the air from measurements based on easy-to-use and low-cost passive sampling, and the conditions of use for the sensors. This document covers samples taken without interruption over periods varying from a few days to one year. This measurement method is applicable to air samples with radon activity concentrations gr...view more

    • sale 15% off
    • Standard
      31 pages
      English language
    • sale 15% off
    • Standard
      31 pages
      French language
    • sale 15% off
    • Draft
      31 pages
      English language
    • sale 15% off
    • Draft
      31 pages
      French language

This document specifies the format of binary list-mode data at the output of digital data acquisition devices used for the detection and measurement of radiation. Such data acquisition devices may employ digital signal processors (DSP) and field-programmable gate arrays (FPGA) in combination with memory and a communication interface with a computer.

    • sale 10% off
    • Standard
      113 pages
      English language
    • e-Library read for
      1 day

The ISO 11929 series specifies a procedure, in the field of ionizing radiation metrology, for the calculation of the "decision threshold", the "detection limit" and the "limits of the coverage interval" for a non-negative ionizing radiation measurand when counting measurements with preselection of time or counts are carried out. The measurand results from a gross count rate and a background count rate as well as from further quantities on the basis of a model of the evaluation. In particular, th...view more

    • sale 10% off
    • Standard
      50 pages
      English language
    • e-Library read for
      1 day

The ISO 11929 series specifies a procedure, in the field of ionizing radiation metrology, for the calculation of the "decision threshold", the "detection limit" and the "limits of the coverage interval" for a non-negative ionizing radiation measurand when counting measurements with preselection of time or counts are carried out. The measurand results from a gross count rate and a background count rate as well as from further quantities on the basis of a model of the evaluation. In particular, th...view more

    • sale 10% off
    • Standard
      48 pages
      English language
    • e-Library read for
      1 day

IEC 60675-3 applies to electric direct-acting room heaters.This document defines performance characteristics related to the radiant effect and specifiesmethods for measuring the radiation efficiency for the information of users.This document is used to measure the radiation efficiency of direct-acting room heaters.

    • sale 10% off
    • Standard
      46 pages
      English language
    • e-Library read for
      1 day

This clause of IEC 60675:1994 is applicable, with the following modification:
Replace the first paragraph with the following content:
This document applies to electric direct-acting room heaters .
This document defines performance characteristics related to the radiant effect and specifies
methods for measuring the radiant factor for the information of users.
This document is used to measure the radiant factor of direct-acting room heaters.

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day

This document gives guidelines on additional aspects of the characterization of low energy photon radiations and on the procedures for calibration and determination of the response of area and personal dose(rate)meters as a function of photon energy and angle of incidence. This document concentrates on the accurate determination of conversion coefficients from air kerma to Hp(10), H*(10), Hp(3) and H'(3) and for the spectra of low energy photon radiations. As an alternative to the use of convers...view more

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for
      1 day

This document specifies additional procedures and data for the calibration of dosemeters and doserate meters used for individual and area monitoring in radiation protection. The general procedure for the calibration and the determination of the response of radiation protection dose(rate)meters is described in ISO 29661 and is followed as far as possible. For this purpose, the photon reference radiation fields with mean energies between 8 keV and 9 MeV, as specified in ISO 4037-1, are used. In An...view more

    • sale 10% off
    • Standard
      77 pages
      English language
    • e-Library read for
      1 day

This document specifies the procedures for the dosimetry of X and gamma reference radiation for the calibration of radiation protection instruments over the energy range from approximately 8 keV to 1,3 MeV and from 4 MeV to 9 MeV and for air kerma rates above 1 µGy/h. The considered measuring quantities are the air kerma free-in-air, Ka, and the phantom related operational quantities of the International Commission on Radiation Units and Measurements (ICRU)[2], H*(10), Hp(10), H'(3), Hp(3), H'(0...view more

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day

This document specifies the characteristics and production methods of X and gamma reference radiation for calibrating protection-level dosemeters and doserate meters with respect to the phantom related operational quantities of the International Commission on Radiation Units and Measurements (ICRU)[5]. The lowest air kerma rate for which this standard is applicable is 1 µGy h?1. Below this air kerma rate the (natural) background radiation needs special consideration and this is not included in t...view more

    • sale 10% off
    • Standard
      56 pages
      English language
    • e-Library read for
      1 day

The ISO 11929 series specifies a procedure, in the field of ionizing radiation metrology, for the calculation of the "decision threshold", the "detection limit" and the "limits of the coverage interval" for a non-negative ionizing radiation measurand when counting measurements with preselection of time or counts are carried out. The measurand results from a gross count rate and a background count rate as well as from further quantities on the basis of a model of the evaluation. In particular, th...view more

    • sale 10% off
    • Standard
      49 pages
      English language
    • e-Library read for
      1 day

This document describes the method of measuring, evaluating and specifying the UV irradiation
characteristics of fluorescent ultraviolet lamps that are used in appliances for tanning purposes.
It includes specific requirements regarding the marking of such lamps.
These requirements relate only to type testing.
Lamps complying with the requirements of this document comply with the electrical and
mechanical safety requirements of IEC 61195 and IEC 61199 with the exception of the
requirements...
view more

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day

These international guidelines are based on the assumption that monitoring of environmental components (atmosphere, water, soil and biota) as well as food quality ensure the protection of human health[2][4][5][6][7][8]. The guidelines constitute a basis for the setting of national regulations and standards, inter alia, for monitoring air, water and food in support of public health, specifically to protect the public from ionizing radiation. This document provides — guidance to collect data neede...view more

    • sale 15% off
    • Standard
      30 pages
      English language
    • sale 15% off
    • Draft
      30 pages
      English language

This standard describes the requirements for rapid testing of water samples under emergency situations in laboratories:
- taking into account a special context for analyses, e.g. an unknown and unusual contamination;
- using or adapting if possible radioactivity measurements methods used in routine to get a result
rapidly or applying specific rapid methods previously tested by the laboratory, e.g. for 89Sr determination ;
- preparing the laboratory to analyse a large number of potentially co...
view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

This document specifies a method for the measurement of 210Po in all types of waters by alpha
spectrometry.
The method is applicable to test samples of supply/drinking water, rainwater, surface and ground
water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater
after proper sampling and handling, and test sample preparation. Filtration of the test sample may be
required.
The detection limit depends on the sample volume, the instrument used, the c...
view more

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day

IEC 61228:2020 is available as IEC 61228:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61228:2020 describes the method of measuring, evaluating and specifying the UV irradiation characteristics of fluorescent ultraviolet lamps that are used in appliances for tanning purposes. It includes specific requirements regarding the marking of such lamps. This third edition cancels and replaces...
view more

    • sale 15% off
    • Standard
      38 pages
      English and French language

This document specifies a procedure, in the field of ionizing radiation metrology, for the calculation of the "decision threshold", the "detection limit" and the "limits of the coverage interval" for a non‑negative ionizing radiation measurand when counting measurements with preselection of time or counts are carried out. The measurand results from a gross count rate and a background count rate as well as from further quantities on the basis of a model of the evaluation. In particular, the measu...view more

    • sale 15% off
    • Standard
      97 pages
      English language
    • sale 15% off
    • Standard
      99 pages
      French language
    • sale 15% off
    • Draft
      97 pages
      English language
    • sale 15% off
    • Draft
      99 pages
      French language

This document provides guidelines for testing laboratories wanting to use rapid test methods on water samples that may be contaminated following a nuclear or radiological emergency incident. In an emergency situation, consideration should be given to: — taking into account the specific context for the tests to be performed, e.g. a potentially high level of contamination; — using or adjusting, when possible, radioactivity test methods implemented during routine situations to obtain a result rapid...view more

    • sale 15% off
    • Standard
      20 pages
      English language
    • sale 15% off
    • Standard
      22 pages
      French language
    • sale 15% off
    • Draft
      20 pages
      English language

This document specifies methods and procedures for characterizing the responses of devices used
for the determination of ambient dose equivalent for the evaluation of exposure to cosmic radiation in
civilian aircraft. The methods and procedures are intended to be understood as minimum requirements.

    • sale 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day

This document specifies a method for the measurement of 210Po in all types of waters by alpha spectrometry. The method is applicable to test samples of supply/drinking water, rainwater, surface and ground water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling, and test sample preparation. Filtration of the test sample may be required. The detection limit depends on the sample volume, the instrument used, the countin...view more

    • sale 15% off
    • Standard
      19 pages
      English language
    • sale 15% off
    • Standard
      20 pages
      French language
    • sale 15% off
    • Draft
      19 pages
      English language

The purpose of this document is to provide minimum criteria required for quality assurance and quality control, evaluation of the performance and to facilitate the comparison of measurements related to absorbed dose estimation obtained in different laboratories applying ex vivo X-band EPR spectroscopy with human tooth enamel. This document covers the determination of absorbed dose in tooth enamel (hydroxyapatite). It does not cover the calculation of dose to organs or to the body. This document ...view more

    • sale 15% off
    • Standard
      22 pages
      English language
    • sale 15% off
    • Draft
      22 pages
      English language

The primary purpose of this document is to provide minimum acceptable criteria required to establish a procedure for retrospective dosimetry by electron paramagnetic resonance spectroscopy and to report the results. The second purpose is to facilitate the comparison of measurements related to absorbed dose estimation obtained in different laboratories. This document covers the determination of absorbed dose in the measured material. It does not cover the calculation of dose to organs or to the b...view more

    • sale 15% off
    • Standard
      19 pages
      English language
    • sale 15% off
    • Standard
      21 pages
      French language
    • sale 15% off
    • Draft
      19 pages
      English language

This practice covers dosimetric procedures to be followed in installation qualification, operational qualification and performance qualification (IQ, OQ, PQ), and routine processing at electron beam facilities to ensure that the product has been treated with an acceptable range of absorbed doses. Other procedures related to IQ, OQ, PQ, and routine product processing that may influence absorbed dose in the product are also discussed. The electron beam energy range covered in this practice is betw...view more

    • sale 15% off
    • Standard
      13 pages
      English language
    • sale 15% off
    • Draft
      13 pages
      English language

This document specifies the characteristics of reference measurement standards of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This document relates to alpha-emitters, beta-emitters, and photon emitters of maximum photon energy not greater than 1,5 MeV. It does not describe the procedures involved in the use of these reference measurement standards for the calibration of surface contamination monitors. Such...view more

    • sale 15% off
    • Standard
      13 pages
      English language
    • sale 15% off
    • Standard
      14 pages
      French language
    • sale 15% off
    • Draft
      13 pages
      English language

EN-IEC 60580 specifies the performance and testing of DOSE AREA PRODUCT METERS intended to measure DOSE AREA PRODUCT and/or DOSE AREA PRODUCT RATE to which the PATIENT is exposed during MEDICAL RADIOLOGICAL EXAMINATIONS. This document is applicable to the following types of DOSE AREA PRODUCT METERS: a) FIELD-CLASS DOSE AREA PRODUCT METERS normally used for the measurement of DOSE AREA PRODUCTS during MEDICAL RADIOLOGICAL EXAMINATIONS; b) REFERENCE-CLASS DOSE AREA PRODUCT METERS normally used for...view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day

This procedure specifies a method for the determination of 228Ra activity in drinking waters by radium
extraction, purification and liquid scintillation counting.

    • sale 10% off
    • Standard
      37 pages
      English language
    • e-Library read for
      1 day

ISO 13164-1:2013 gives general guidelines for sampling, packaging, and transporting of all kinds of water samples, for the measurement of the activity concentration of radon-222.
The test methods fall into two categories: a) direct measurement of the water sample without any transfer of phase (see ISO 13164‑2); b) indirect measurement involving the transfer of the radon-222 from the aqueous phase to another phase (see ISO 13164‑3).
The test methods can be applied either in the laboratory or on...
view more

    • sale 10% off
    • Standard
      33 pages
      English language
    • e-Library read for
      1 day

ISO 13165-3:2016 specifies the determination of radium-226 (226Ra) activity concentration in all types of water by coprecipitation followed by gamma-spectrometry (see ISO 18589‑3).
The method described is suitable for determination of soluble 226Ra activity concentrations greater than 0,02 Bq l−1 using a sample volume of 1 l to 100 l of any water type.
For water samples smaller than a volume of 1 l, direct gamma-spectrometry can be performed following ISO 10703 with a higher detection limit.
...
view more

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day

ISO 13165-2:2014 specifies the determination of radium-226 (226Ra) activity concentration in all types of water by emanometry. The method specified is suitable for the determination of the soluble, suspended, and total 226Ra activity concentration in all types of water with soluble 226Ra activity concentrations greater than 0,02 Bq l−1. In water containing high activity concentrations of 228Th, interference from 220Rn decay products can lead to overestimation of measured levels.

    • sale 10% off
    • Standard
      23 pages
      English language
    • e-Library read for
      1 day

ISO 13164-2:2013 specifies a test method for the determination of radon-222 activity concentration in a sample of water following the measurement of its short-lived decay products by direct gamma-spectrometry of the water sample.
The radon-222 activity concentrations, which can be measured by this test method utilizing currently available gamma-ray instruments, range from a few becquerels per litre to several hundred thousand becquerels per litre for a 1 l test sample.
This test method can be ...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

ISO 13164-3:2013 specifies a test method for the determination of radon-222 activity concentration in a sample of water following its transfer from the aqueous phase to the air phase by degassing and its detection. It gives recommendations for rapid measurements performed within less than 1 h.
The radon-222 activity concentrations, which can be measured by this test method utilizing currently available instruments, range from 0,1 Bq l−1 to several hundred thousand becquerels per litre for a 100...
view more

    • sale 10% off
    • Standard
      31 pages
      English language
    • e-Library read for
      1 day

ISO 13164-4:2015 describes a test method for the determination of radon-222 (222Rn) activity concentration in non-saline waters by extraction and liquid scintillation counting.
The radon-222 activity concentrations, which can be measured by this test method utilizing currently available instruments, are at least above 0,5 Bq l−1 for a 10 ml test sample and a measuring time of 1 h.
This test method can be used successfully with drinking water samples and it is the responsibility of the laborato...
view more

    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day

ISO 13165-1:2013 specifies the determination of radium-226 (226Ra) activity concentration in non-saline water samples by extraction of its daughter radon-222 (222Rn) and its measurement using liquid scintillation counting.
Radium-226 activity concentrations which can be measured by this test method utilizing currently available liquid scintillation counters goes down to 50 mBq l−1. This method is not applicable to the measurement of other radium isotopes.

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day

ISO 19581 specifies a screening test method to quantify rapidly the activity concentration of gamma-emitting radionuclides, such as 131I, 132Te, 134Cs and 137Cs, in solid or liquid test samples using gamma-ray spectrometry with lower resolution scintillation detectors as compared with the HPGe detectors (see IEC 61563).
This test method can be used for the measurement of any potentially contaminated environmental matrices (including soil), food and feed samples as well as industrial materials o...
view more

    • sale 10% off
    • Standard
      27 pages
      English language
    • e-Library read for
      1 day

ISO 19361:2017 applies to liquid scintillation counters and requires the preparation of a scintillation source obtained by mixing the test sample and a scintillation cocktail. The test sample can be liquid (aqueous or organic), or solid (particles or filter or planchet).
ISO 19361:2017describes the conditions for measuring the activity of beta emitter radionuclides by liquid scintillation counting[14][15].
The choice of the test method using liquid scintillation counting involves the considera...
view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance on the selection of dosimetry systems and directs the user to other standards that provide specific information on individual dosimetry systems, calibration methods, uncertainty estimation and radiation processing applications. This practice applies to dosimetry for radiation processing applications using...view more

    • sale 15% off
    • Standard
      13 pages
      English language

ISO 19361:2017 applies to liquid scintillation counters and requires the preparation of a scintillation source obtained by mixing the test sample and a scintillation cocktail. The test sample can be liquid (aqueous or organic), or solid (particles or filter or planchet).
ISO 19361:2017describes the conditions for measuring the activity of beta emitter radionuclides by liquid scintillation counting[14][15].
The choice of the test method using liquid scintillation counting involves the considera...
view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

ISO 19581 specifies a screening test method to quantify rapidly the activity concentration of gamma-emitting radionuclides, such as 131I, 132Te, 134Cs and 137Cs, in solid or liquid test samples using gamma-ray spectrometry with lower resolution scintillation detectors as compared with the HPGe detectors (see IEC 61563).
This test method can be used for the measurement of any potentially contaminated environmental matrices (including soil), food and feed samples as well as industrial materials o...
view more

    • sale 10% off
    • Standard
      27 pages
      English language
    • e-Library read for
      1 day

This practice covers the preparation and use of semiadiabatic calorimetric dosimetry systems for measurement of absorbed dose and for calibration of routine dosimetry systems when irradiated with electrons for radiation processing applications. The calorimeters are either transported by a conveyor past a scanned electron beam or are stationary in a broadened beam. This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing,...view more

    • sale 15% off
    • Standard
      9 pages
      English language

EN-ISO 11665-3 describes spot measurement methods for determining the activity concentration of short-lived radon-222 decay products in the air and for calculating the potential alpha energy concentration.This document gives indications for performing a spot measurement of the potential alpha energy concentration, after sampling at a given place for several minutes, and the conditions of use for the measuring devices.The measurement method described is applicable for a rapid assessment of the po...view more

    • sale 10% off
    • Standard
      27 pages
      English language
    • e-Library read for
      1 day

EN-ISO 11665-5 describes continuous measurement methods for radon-222. It gives indications for continuous measuring of the temporal variations of radon activity concentration in open or confined atmospheres.This document is intended for assessing temporal changes in radon activity concentration in the environment, in public buildings, in homes and in work places, as a function of influence quantities such as ventilation and/or meteorological conditions.The measurement method described is applic...view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

EN-ISO 11665-6 describes radon-222 spot measurement methods. It gives indications for carrying out spot measurements, at the scale of a few minutes at a given place, of the radon activity concentration in open and confined atmospheres.This measurement method is intended for rapid assessment of the radon activity concentration in the air. The result cannot be extrapolated to an annual estimate of the radon activity concentration. This type of measurement is therefore not applicable for assessment...view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

ISO 13164-2:2013 specifies a test method for the determination of radon-222 activity concentration in a sample of water following the measurement of its short-lived decay products by direct gamma-spectrometry of the water sample.
The radon-222 activity concentrations, which can be measured by this test method utilizing currently available gamma-ray instruments, range from a few becquerels per litre to several hundred thousand becquerels per litre for a 1 l test sample.
This test method can be ...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

ISO 13164-4:2015 describes a test method for the determination of radon-222 (222Rn) activity concentration in non-saline waters by extraction and liquid scintillation counting.
The radon-222 activity concentrations, which can be measured by this test method utilizing currently available instruments, are at least above 0,5 Bq l−1 for a 10 ml test sample and a measuring time of 1 h.
This test method can be used successfully with drinking water samples and it is the responsibility of the laborato...
view more

    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day

ISO 13165-2:2014 specifies the determination of radium-226 (226Ra) activity concentration in all types of water by emanometry. The method specified is suitable for the determination of the soluble, suspended, and total 226Ra activity concentration in all types of water with soluble 226Ra activity concentrations greater than 0,02 Bq l−1. In water containing high activity concentrations of 228Th, interference from 220Rn decay products can lead to overestimation of measured levels.

    • sale 10% off
    • Standard
      23 pages
      English language
    • e-Library read for
      1 day

ISO 13164-3:2013 specifies a test method for the determination of radon-222 activity concentration in a sample of water following its transfer from the aqueous phase to the air phase by degassing and its detection. It gives recommendations for rapid measurements performed within less than 1 h.
The radon-222 activity concentrations, which can be measured by this test method utilizing currently available instruments, range from 0,1 Bq l−1 to several hundred thousand becquerels per litre for a 100...
view more

    • sale 10% off
    • Standard
      31 pages
      English language
    • e-Library read for
      1 day

ISO 13165-3:2016 specifies the determination of radium-226 (226Ra) activity concentration in all types of water by coprecipitation followed by gamma-spectrometry (see ISO 18589‑3).
The method described is suitable for determination of soluble 226Ra activity concentrations greater than 0,02 Bq l−1 using a sample volume of 1 l to 100 l of any water type.
For water samples smaller than a volume of 1 l, direct gamma-spectrometry can be performed following ISO 10703 with a higher detection limit.
...
view more

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day