This document applies to basic safety and essential performance of cerebral tissue oximeter equipment, that employs light at multiple wavelengths to derive a quantitative measure of oxygen saturation of haemoglobin within the volume of tissue sampled under the probe attached to the head. The cerebral tissue oximeter equipment can be based on continuous light, frequency domain or time domain technologies. This document applies to ME equipment used in a hospital environment as well as when used ou...view more

    • sale 15% off
    • Standard
      107 pages
      English language
    • sale 15% off
    • Standard
      108 pages
      English language
    • sale 15% off
    • Standard
      128 pages
      French language
    • sale 15% off
    • Standard
      126 pages
      French language

This document specifies requirements for the basic safety and essential performance of an oxygen concentrator in combination with its accessories, hereafter referred to as ME equipment, intended to increase the oxygen concentration of gas intended to be delivered to a single patient. Such oxygen concentrators are typically intended for use in the home healthcare environment by a single patient in various environments including any private and public transportation as well as in commercial aircra...view more

    • sale 10% off
    • Standard
      73 pages
      English language
    • e-Library read for
      1 day

This particular standard is applicable to the basic safety and essential performance of oxygen conserving equipment, hereafter referred to as me equipment, in combination with its accessories intended to conserve supplemental oxygen by delivering gas intermittently and synchronized with the patient's inspiratory cycle, when used in the home healthcare environment. Oxygen conserving equipment is typically used by a lay operator.
This particular standard is also applicable to those accessories in...
view more

    • sale 10% off
    • Standard
      67 pages
      English language
    • e-Library read for
      1 day

This particular standard is applicable to the basic safety and essential performance of sleep apnoea breathing therapy equipment, hereafter referred to as ME equipment, intended to alleviate the symptoms of patients who suffer from obstructive sleep apnoea by delivering a therapeutic breathing pressure to the patient. Sleep apnoea breathing therapy equipment is intended for use in the home healthcare environment by lay operators as well as in professional healthcare institutions.
This particu...
view more

    • sale 10% off
    • Standard
      79 pages
      English language
    • e-Library read for
      1 day

This document is applicable to the basic safety and essential performance of sleep apnoea breathing therapy equipment, hereafter referred to as ME equipment, intended to alleviate the symptoms of patients who suffer from obstructive sleep apnoea by delivering a therapeutic breathing pressure to the respiratory tract of the patient. Sleep apnoea breathing therapy equipment is intended for use in the home healthcare environment by lay operators as well as in professional healthcare institutions.
...
view more

    • sale 15% off
    • Standard
      68 pages
      English language

This document is applicable to the basic safety and essential performance of sleep apnoea breathing therapy equipment, hereafter referred to as ME equipment, intended to alleviate the symptoms of patients who suffer from obstructive sleep apnoea by delivering a therapeutic breathing pressure to the respiratory tract of the patient. Sleep apnoea breathing therapy equipment is intended for use in the home healthcare environment by lay operators as well as in professional healthcare institutions. *...view more

    • sale 15% off
    • Standard
      68 pages
      English language
    • sale 15% off
    • Standard
      68 pages
      French language
    • sale 15% off
    • Draft
      67 pages
      English language
    • sale 15% off
    • Draft
      73 pages
      French language

This document specifies dimensions and requirements for both open and closed suction catheters made
of flexible materials and intended for use in suctioning of the respiratory tract.
Suction catheters intended for use with flammable anaesthetic gases or agents, lasers or electrosurgical
equipment are not covered by this document.
NOTE For guidance on airway management during laser surgery of the upper airway, see ISO/TR 11991[4].

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for the basic safety and essential performance of an oxygen concentrator in combination with its accessories, hereafter referred to as ME equipment, intended to increase the oxygen concentration of gas intended to be delivered to a single patient. Such oxygen concentrators are typically intended for use in the home healthcare environment by a single patient in various environments including any private and public transportation as well as in commercial aircra...view more

    • sale 15% off
    • Standard
      67 pages
      English language

This document specifies requirements for the basic safety and essential performance of an oxygen concentrator in combination with its accessories, hereafter referred to as ME equipment, intended to increase the oxygen concentration of gas intended to be delivered to a single patient. Such oxygen concentrators are typically intended for use in the home healthcare environment by a single patient in various environments including any private and public transportation as well as in commercial aircra...view more

    • sale 15% off
    • Draft
      62 pages
      English language
    • sale 15% off
    • Draft
      68 pages
      French language

This document is applicable to the basic safety and essential performance of oxygen conserving equipment, hereafter referred to as ME equipment, in combination with its accessories intended to conserve supplemental oxygen by delivering gas intermittently and synchronized with the patient's inspiratory cycle, when used in the home healthcare environment. Oxygen conserving equipment is typically used by a lay operator.
NOTE 1 Conserving equipment can also be used in professional health care facil...
view more

    • sale 15% off
    • Standard
      57 pages
      English language

This document is applicable to the basic safety and essential performance of oxygen conserving equipment, hereafter referred to as ME equipment, in combination with its accessories intended to conserve supplemental oxygen by delivering gas intermittently and synchronized with the patient's inspiratory cycle, when used in the home healthcare environment. Oxygen conserving equipment is typically used by a lay operator. NOTE 1 Conserving equipment can also be used in professional health care facili...view more

    • sale 15% off
    • Standard
      57 pages
      English language
    • sale 15% off
    • Standard
      61 pages
      French language
    • sale 15% off
    • Draft
      57 pages
      English language
    • sale 15% off
    • Draft
      63 pages
      French language

This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT
TRANSPORT INCUBATOR equipment, as defined in 201.3.208, also referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the
case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
HAZARDS inherent in the intended ...
view more

    • sale 10% off
    • Standard
      47 pages
      English language
    • e-Library read for
      1 day

This document, which is device-specific, specifies requirements for laryngoscopes with non-flexible
blades, with internal battery-operated power sources, used for illuminating the larynx during
intubation. It also specifies critical dimensions for those handles and laryngoscope blades with
interchangeable hook‐on fittings.
It is not applicable to the following:
— flexible laryngoscopes;
— laryngoscopes designed for surgery;
— laryngoscopes powered from mains electricity supply;
— laryngo...
view more

    • sale 10% off
    • Standard
      24 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      9 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      6 pages
      English language
    • e-Library read for
      1 day

This document gives requirements for labels attached to syringes so that the contents can be identified just before use during anaesthesia. It covers the colour, size, design and general properties of the label and the typographical characteristics of the wording for the drug name. NOTE National or regional regulations might require additional labelling, which can include bar coding. No requirements for this additional labelling are given.

    • sale 15% off
    • Standard
      9 pages
      English language

IEC 60601-2-21:2020 is available as IEC 60601-2-21:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60601-2-21:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and conten...
view more

    • sale 15% off
    • Standard
      77 pages
      English and French language
    • sale 15% off
    • Standard
      58 pages
      English language
    • sale 15% off
    • Amendment with corrigendum
      56 pages
      French language
    • sale 15% off
    • Draft
      54 pages
      English language

IEC 60601-2-20:2020 is available as IEC 60601-2-20:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60601-2-20:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT TRANSPORT INCUBATOR equipment, as defined in 201.3.208, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the t...
view more

    • sale 15% off
    • Standard
      44 pages
      English language

IEC 60601-2-19:2020 is available as IEC 60601-2-19:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60601-2-19:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT INCUBATORS, as defined in 201.3.209, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of...
view more

    • sale 15% off
    • Standard
      39 pages
      English language

This document, which is device-specific, specifies requirements for laryngoscopes with non-flexible blades, with internal battery-operated power sources, used for illuminating the larynx during intubation. It also specifies critical dimensions for those handles and laryngoscope blades with interchangeable hook‐on fittings. It is not applicable to the following: — flexible laryngoscopes; — laryngoscopes designed for surgery; — laryngoscopes powered from mains electricity supply; — laryngoscopes c...view more

    • sale 15% off
    • Standard
      16 pages
      English language
    • sale 15% off
    • Standard
      17 pages
      French language
    • sale 15% off
    • Standard
      17 pages
      French language
    • sale 15% off
    • Draft
      16 pages
      English language

This document is intended especially to ensure the gas-specific assembly, mechanical resistance, flow,
leakage and pressure drop of terminal units and to prevent their interchange between different gases
and services and applies to terminal units:
a) intended for use in medical gas pipeline systems in accordance with ISO 7396-1;
b) used as pressure outlets on pressure regulators in accordance with ISO 10524-1;
c) used as pressure outlets on pressure regulators integrated with cylinder valve...
view more

    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day

This document applies to the basic safety and essential performance of an EMS ventilator in combination with its accessories, hereafter also referred to as ME equipment: intended for patients who need differing levels of support from artificial ventilation including ventilator-dependent patients; intended to be operated by a healthcare professional operator; intended for use in the EMS environment; and intended for invasive or non-invasive ventilation. NOTE 1 An EMS ventilator can also be used f...view more

    • sale 15% off
    • Standard
      110 pages
      English language
    • sale 15% off
    • Standard
      110 pages
      English language
    • sale 15% off
    • Standard
      122 pages
      French language
    • sale 15% off
    • Standard
      122 pages
      French language

This document applies to the basic safety and essential performance of an EMS ventilator in combination with its accessories, hereafter also referred to as ME equipment:
- intended for patients who need differing levels of support from artificial ventilation including ventilator-dependent patients;
- intended to be operated by a healthcare professional operator;
- intended for use in the EMS environment; and
- intended for invasive or non-invasive ventilation.
NOTE 1 An EMS ventilator can a...
view more

    • sale 15% off
    • Standard
      110 pages
      English language

EN-ISO 80601-2-12 applies to the basic safety and essential performance of a ventilator in combinationwith its accessories, hereafter referred to as ME equipment:- intended for use in an environment that provides specialized care for patients whoseconditions can be life-threatening and who can require comprehensive care and constantmonitoring in a professional healthcare facility;considered as an emergency medical services environment ventilator.- intended to be operated by a healthcare professi...view more

    • sale 10% off
    • Standard
      150 pages
      English language
    • e-Library read for
      1 day

ISO 18562-3:2017 specifies tests for the emissions of volatile organic compounds (vocs) from the gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a patient in all environments. The tests of this document are intended to quantify emissions of vocs that are added to the respirable gas stream by the materials of the gas pathway. This document establishes acceptance criteria for these tests.
...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

ISO 18562-2:2017 specifies tests for the emissions of particulate matter from the gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a patient in all environments. The tests of this document are intended to quantify particles from 0,2 µm diameter to 10 µm diameter that are emitted by the medical device, its parts or accessories into the respirable gas stream. This document establishes accept...view more

    • sale 10% off
    • Standard
      24 pages
      English language
    • e-Library read for
      1 day

ISO 18562-1:2017 specifies:
- the general principles governing the biological evaluation within a risk management process of the gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a patient in all environments;
- the general categorization of gas pathways based on the nature and duration of their contact with the gas stream;
- the evaluation of existing relevant data from all sources;
- ...
view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

ISO 80601-2-74:2017 applies to the basic safety and essential performance of a humidifier, also hereafter referred to as me equipment, in combination with its accessories, the combination also hereafter referred to as me system.
ISO 80601-2-74:2017 is also applicable to those accessories intended by their manufacturer to be connected to a humidifier where the characteristics of those accessories can affect the basic safety or essential performance of the humidifier.
EXAMPLE 1 Heated breathing ...
view more

    • sale 10% off
    • Standard
      99 pages
      English language
    • e-Library read for
      1 day

ISO 17510:2015 applies to masks and their accessories used to connect a sleep apnoea breathing therapy equipment to the patient. It specifies requirements for masks and accessories, including any connecting element, that are required to connect the patient-connection port of sleep apnoea breathing therapy equipment to a patient for the application of sleep apnoea breathing therapy (e.g. nasal masks, exhaust ports and headgear).

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day

This document applies to the basic safety and essential performance of a ventilator in combination with its accessories, hereafter referred to as ME equipment:
intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility;
NOTE 1 For the purposes of this document, such an environment is referred to as a critical care environment. Venti...
view more

    • sale 10% off
    • Standard
      150 pages
      English language
    • e-Library read for
      1 day

ISO 18562-4:2017 specifies tests for substances leached by liquid water condensing into gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a patient in all environments. The tests of this document are intended to quantify hazardous water-soluble substances that are leached from the medical device, its parts or accessories by condensate and then conveyed by that liquid to the patient. This do...view more

    • sale 10% off
    • Standard
      18 pages
      English language
    • e-Library read for
      1 day

This document applies to the basic safety and essential performance of a ventilator in combination with its accessories, hereafter referred to as ME equipment: intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility; NOTE 1 For the purposes of this document, such an environment is referred to as a critical care environment. Ventilato...view more

    • sale 15% off
    • Standard
      138 pages
      English language
    • sale 15% off
    • Standard
      142 pages
      French language

This document applies to the basic safety and essential performance of a ventilator in combination with its accessories, hereafter referred to as ME equipment:
intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility;  
NOTE 1 For the purposes of this document, such an environment is referred to as a critical care environment. Vent...
view more

    • sale 15% off
    • Standard
      138 pages
      English language

ISO 18562-1:2017 specifies:
- the general principles governing the biological evaluation within a risk management process of the gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a patient in all environments;
- the general categorization of gas pathways based on the nature and duration of their contact with the gas stream;
- the evaluation of existing relevant data from all sources;
- ...
view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

ISO 18562-2:2017 specifies tests for the emissions of particulate matter from the gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a patient in all environments. The tests of this document are intended to quantify particles from 0,2 µm diameter to 10 µm diameter that are emitted by the medical device, its parts or accessories into the respirable gas stream. This document establishes accept...view more

    • sale 10% off
    • Standard
      24 pages
      English language
    • e-Library read for
      1 day

ISO 80601-2-74:2017 applies to the basic safety and essential performance of a humidifier, also hereafter referred to as me equipment, in combination with its accessories, the combination also hereafter referred to as me system.
ISO 80601-2-74:2017 is also applicable to those accessories intended by their manufacturer to be connected to a humidifier where the characteristics of those accessories can affect the basic safety or essential performance of the humidifier.
EXAMPLE 1 Heated breathing ...
view more

    • sale 10% off
    • Standard
      99 pages
      English language
    • e-Library read for
      1 day

ISO 17510:2015 applies to masks and their accessories used to connect a sleep apnoea breathing therapy equipment to the patient. It specifies requirements for masks and accessories, including any connecting element, that are required to connect the patient-connection port of sleep apnoea breathing therapy equipment to a patient for the application of sleep apnoea breathing therapy (e.g. nasal masks, exhaust ports and headgear).

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day

ISO 18562-3:2017 specifies tests for the emissions of volatile organic compounds (vocs) from the gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a patient in all environments. The tests of this document are intended to quantify emissions of vocs that are added to the respirable gas stream by the materials of the gas pathway. This document establishes acceptance criteria for these tests.
...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

ISO 18562-4:2017 specifies tests for substances leached by liquid water condensing into gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a patient in all environments. The tests of this document are intended to quantify hazardous water-soluble substances that are leached from the medical device, its parts or accessories by condensate and then conveyed by that liquid to the patient. This do...view more

    • sale 10% off
    • Standard
      18 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for the repeatability and reproducibility of non-invasive blood pressure (NIBP) simulators intended to test automated sphygmomanometers utilizing the oscillometric non-continuous method only.
In addition, the pulse rate set on the NIBP simulator is tested.
This document is not intended to relate the signals, generated by the NIBP simulator, to the oscillometric signal recorded in a cuff attached to a human. It does not intend to test the interaction between...
view more

    • sale 15% off
    • Technical specification
      11 pages
      English language

This document specifies requirements for the repeatability and reproducibility of non-invasive blood pressure (NIBP) simulators intended to test automated sphygmomanometers utilizing the oscillometric non-continuous method only. In addition, the pulse rate set on the NIBP simulator is tested. This document is not intended to relate the signals, generated by the NIBP simulator, to the oscillometric signal recorded in a cuff attached to a human. It does not intend to test the interaction between t...view more

    • sale 15% off
    • Technical specification
      11 pages
      English language

EN ISO 80601-2-13 was published in 2011. Amendment 1 to EN ISO 80601-2-13:2011 will update this standard with regard to references to IEC 60601-1:2005 (EN 60601-1:2006) and applicable collateral standards. The Amendment 1 also introduces technical modifications to clarify the relationship between this standard and IEC 60601-2-49 and to further specify accessories. It amends requirements on the following aspects, in part due to the publication of amendments that have been published in 2012 and 20...view more

    • sale 10% off
    • Amendment
      18 pages
      English language
    • e-Library read for
      1 day

2019-10-07: CEN/BT 169/2019: remove link to MDD + MDR & publish without delay
2019-10-09 - JO- BT decision - BT N 11739 - remove link to MDD
20180720 - TAN - Consultant assessment rejected
CEN/BT C082/2011:  DOW = DAV + 36 months

    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      6 pages
      English language
    • e-Library read for
      1 day

This International Standard specifies requirements and test methods for amalgam separators used in connection with dental equipment in the dental treatment centre. It specifies the efficiency of the amalgam separators in terms of the level of retention of amalgam based on a laboratory test and the test procedure for determining this efficiency. It also includes requirements for the safe functioning of the amalgam separator, for marking, and for instructions for use, operation and maintenance. Al...view more

    • sale 10% off
    • Amendment
      7 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      3 pages
      English language
    • sale 15% off
    • Standard
      3 pages
      French language

This document specifies dimensions and requirements for both open and closed suction catheters made of flexible materials and intended for use in suctioning of the respiratory tract. Suction catheters intended for use with flammable anaesthetic gases or agents, lasers or electrosurgical equipment are not covered by this document. NOTE For guidance on airway management during laser surgery of the upper airway, see ISO/TR 11991[4].

    • sale 15% off
    • Standard
      24 pages
      English language
    • sale 15% off
    • Standard
      24 pages
      French language